System setup
Function 
Settings & Options
Note: 
Depending on system settings, functions on this page might not appear.
0180
Heating Fan 
Control
Gas or oil heat: Use this setting if you have a gas or oil heating system 
(system controls fan operation).
Electric heat: Use this setting if you have an electric heating system 
(thermostat controls fan operation).
0190
Heat Pump 
Changeover Valve 
(for heat pumps 
only)
Cooling changeover valve: Use this setting if you connected a wire 
labeled “O” to the O/B terminal.
Heating changeover valve: Use this setting if you connected a wire 
labeled “B” to the O/B terminal.
0240
Heating Cycle  
Rate
Gas or oil furnace: Standard gas/oil furnace (less than 90% efficiency).
Electric furnace: Electric heating systems.
Hot water or high-efficiency furnace: Hot water system or gas furnace 
(more than 90% efficiency).
Gas/oil steam or gravity system: Steam or gravity heat systems.
0250
Heating Cycle  
Rate Stage 2
How do I customize my heating/cooling system? (See page 51 for instructions.)