Powerwave Technologies Inc. MCPS2135 Manuale Utente

Pagina di 46
MCPS2135 InstallationPlanning and Preparation
Introduction
 
18 
MCPS2135 Operations Manual 
2001 Spectrian Corporation.  All rights reserved.
 
with local building codes and industry practice.  Refer to Table 2 for the 
recommended power supply circuit and wire sizing for each option.  
WARNING:  Do not perform DC lead installation with energized leads.  Ensure 
that the DC power supply is OFF for all installation activities!
 
1.  Locate the positive and n egative terminals on the customer-provided DC 
power source, and verify polarity with a DVM. 
2.  Locate the power supply lugs at the top of the rear of the shelf 
subassembly.  The four #10 lugs are for the per-RF-Module connection 
option, the single pair of ¼” lugs are for the bussed power option.  
Determine which set of lugs will be used for this installation. 
3.  Measure the distance and routing between the power source and the 
MCPS2135 DC lugs.  
4.  For each power connection being made, cut equal lengths of wire for 
power and return.  Strip and connect each wire to the appropriate power 
connection, using the crimping tool and the supplied ground lug. 
∗ 
Caution:  Verify the polarity of each supply wire prior to connecting them to the 
shelf subassembly.  A reversed-polarity connection will severely damage the 
MCPS2135 and will void the product warranty. 
5.  Crimp the appropriate terminal lugs onto each power supply wire. 
6.  Attach one positive supply  wire and one return wire to each of the four 
sets the power supply lugs at the top of the rear of the shelf subassembly. 
Tighten the attachment nuts firmly. 
7.  Inspect the finished connection.  If no problems exist, the DC input power 
cable installation is complete. 
3.4.3 Connect RF Output and Input Cables 
The MCPS2135 has one
 
female type-N amplified RF output for connection to a 
customer-supplied coaxial cable terminated with a male connector, and one female 
SMA RF input for connection to an customer-supplied input cable terminated with 
a male SMA connector. 
WARNING:  Do not perform RF cable installation with DC power applied to the 
MCPS2135.  Ensure that the input DC power supply is OFF before handling RF 
cables. 
∗ 
Caution:  The Output cable must be connected before connecting the Input 
cable. 
Note:  The integrity of RF cabling  is critical to the electrical performance of the 
MCPS2135.  Ensure connectors are properly assembled, are free of debris, and 
are clean. 
1.  Locate the male N-type RF output connector on the end of the coaxial 
cable attached to the output load.  Inspect the connector and clean if 
necessary; fix any problems with the cable or connector before 
proceeding.