ZyXEL Communications Corporation 5VZ-A2011 Manuale Utente
Chapter 25 Diagnostic
CellPipe 7130 RG User’s Guide
284
• Loopback test - checks if the MEP port receives its Loop Back Response (LBR)
from its target after it sends the Loop Back Message (LBM). If no response is
received, there might be a connectivity fault between them.
• Link trace test - provides additional connectivity fault analysis to get more
information on where the fault is. If an MEP port does not respond to the source
MEP, this may indicate a fault. Administrators can take further action to check
and resume services from the fault according to the line connectivity status
report.
25.3 The General Diagnostic Screen
Click Maintenance > Diagnostic to open the screen shown next. Ping and
traceroute help check availability of remote hosts and also help troubleshoot
network or Internet connections.
traceroute help check availability of remote hosts and also help troubleshoot
network or Internet connections.
Figure 138 Maintenance > Diagnostic > General
The following table describes the fields in this screen.
Table 97 Maintenance > Diagnostic > General
LABEL
DESCRIPTION
TCP/IP
Address
Address
Type the IP address of a computer that you want to ping in order to test a
connection or trace the route packets take to.
connection or trace the route packets take to.
Ping
Click this button to ping the IP address that you entered.
Traceoute
Click this button to perform the traceroute function. This determines the
path a packet takes to the specified host.
path a packet takes to the specified host.