COOPER INDUSTRIES INC 2072 Manuale Utente

Pagina di 22
Setup/Calibration  
©PAT Rev. F  03/26/03 
190136_f 
7
5 SETUP/CALIBRATION 
5.1.1 Setup 
Overview 
The PAT RATB is easily configured to communicate with up to 2 transmitters.  Simply by pressing and 
holding the yellow “ID” button for 7 seconds, the receiver can sense the transmitters being used and 
configure the receiver to listen to only those transmitters. There are no numbers, ID’s or codes to 
remember or write down.  
 
 
 
 
5.1.2  Clear Existing Setup Switches 
Press and hold the yellow “ID” button for 15 seconds, the ID LED will begin to blink and then go off 
when cleared. Note: It is only necessary to complete this operation when changing from a duel 
switch setup to a single switch
. When setup is complete, the new transmitter switch will over write 
the old ID code with a new one. 
 
5.1.3  First ID Setup 
To configure the system, install batteries into the transmitter to be used. Turn on the crane power. 
Open the receiver enclosure and slide out the receiver board. Press and hold the yellow ID button on 
the OEM module for 7 seconds until the ID 1 LED blinks. Release the yellow ID button. The receiver 
will search for a transmitter for the next 30 seconds. Pull on the cable of the transmitter and then 
release it. The yellow ID 1 LED should now be on solid. The transmitter and receiver are now set up 
and will work only with each other. 
 
ID SET 
BUTTON