COOPER INDUSTRIES INC FH1847N Manuale Utente

Pagina di 36
T245 Control System Manual
27
Parameter
Display Type
Min. Max. Increm. Default Cannot Go Below
Cannot Go Above
PWM Drive Frequency
for R1300 Proportional
Outputs 1+/- through
4+/-
Solid 1+ Mult.-
Choice
A = 33 Hz
B = 50 Hz
C = 80 Hz
D = 125 Hz
E = 250 Hz
A
N/A
N/A
PWM Drive Frequency
for R1300 Proportional
Outputs 5+/- and 6+/-
Solid 1- Mult.-
Choice
A = 33 Hz
B = 50 Hz
C = 80 Hz
D = 125 Hz
E = 250 Hz
A
N/A
N/A
PWM Drive Frequency
for S20 Proportional
Outputs O1 through O8
Solid 2+ Mult.-
Choice
A = 33 Hz
B = 50 Hz
C = 80 Hz
D = 125 Hz
E = 250 Hz
A
N/A
N/A
PWM Drive Frequency
for S20 Proportional
Outputs O9 through O16
Solid 2- Mult.-
Choice
A = 33 Hz
B = 50 Hz
C = 80 Hz
D = 125 Hz
E = 250 Hz
E
N/A
N/A
Boom Load Moment
Limit
Solid 3+ Mult.-
Choice
A = 2500000 inch-lbs
A
N/A
N/A
Boom Derating Factor,
Ground Operation (%)
Solid 3- Variable
Value
20
150
2
84
N/A
N/A