COOPER INDUSTRIES INC LPT900 Manuale Utente

Pagina di 4
Setting ID Codes
Current Control Module Calibration
Permits the user to adjust minimum and maximum currents
1. Release 
the 
[EStop] on the T150.
2. Turn 
the 
T150 ON by toggling the [SW5] switch to the UP position.
3. While 
holding 
the 
[SW5] switch in the UP position, press and release the [EStop] switch.  This enables the
“Download Password” mode.
4. Release 
the 
[SW5] switch.  The ACTIVE LED will flash once per second.
5.  Toggle the switches in sequence: [SW3], [SW1], [SW4] and then [SW4] to the DOWN position to enter the
password code (3144), followed by toggling the [SW5] switch to the UP position.  The ACTIVE and LOW BATT.
LED’s will flash alternately once per second.  This confirms the T150 is sending “Calibration Data” to the R150.
6.  Select and hold one of the “Proportional Functions” (i.e. [SW4] or [ROT CW]).
7.  With the trigger OFF (fully released), the “MIN” level is set.  The “MIN” level may be increased by toggling the
[SW5] switch up or decreased by toggling the [SW5] switch down.
8.  With the trigger ON (fully engaged), the “MAX” level is set.  The “MAX” level may be increased by toggling the
[SW5] switch up or decreased by toggling the [SW5] switch down.
9.  To reset the “MIN” and “MAX” settings to the factory default, hold the [SW5] switch in either the UP or DOWN
position for 5 seconds.
10.  To exit, press the [EStop] switch.
Required when replacing either the Transmitter or Receiver
The Transmitter has its ID Code factory programmed.  Its matching receiver needs to have this same code
programmed into it.  To do this, the Receiver needs to have its cover removed – refer to Figure 2.  Follow the
procedure below to program the Receiver ID Code to match its corresponding Transmitter.
1. Release 
the 
[EStop] switch on the T150.
2. Turn 
the 
T150 on by toggling the [SW5] switch to the UP position.
3. While 
holding 
the 
[SW5] switch in the UP position, press and release the [EStop] switch. This enables the
“Download Password” mode.
4. Release 
the 
[SW5] switch.  The ACTIVE LED will flash once per second.
5. 
Toggle the switches in sequence: [SW3][SW1][SW4] and then [SW2] to the UP position to enter the
password code (3142), followed by toggling the [SW5] switch to the UP position.  Both the ACTIVE and LOW
BATT.
 LED’s will flash twice per second.  This confirms the unit is in the “Ready to Download” state.
6. 
Press and hold the [SETUP] button on the R150 for 5 seconds.  The STATUS LED on the R150 will flash once
per second while depressed and then begin flashing rapidly indicating that the R150 is ready to receive
“Configuration Data” from the T150.  Continue holding the [SETUP] button after the STATUS LED begins
flashing rapidly.
7. 
Momentarily toggle the [SW5] switch to the UP position; this enables the T150 to send “Configuration Data” to
the R150.  Release [SW5] and release the [SETUP] button.
8.
Press the [EStop] switch to power down the T150, and restart the T150 – refer to STEP 2.