Audiotel International Limited 2-400-0001 Manuale Utente

Pagina di 34
18 
AUDIOTEL INTERNATIONAL MN400872 Issue 1 (08/04) 
D
ETECT
IV User Manual
AUDIOTEL INTERNATIONAL MN400872 Issue 1 (08/04) 
19
IDENTIFY 
MODE
This mode is used to positively identify a suspect signal as 
a potential eavesdropping device within the search area.
To select the IDENTIFY mode 
From the Detect screen
       select the appropriate detector
       press the IDENTIFY  on-screen button.
The IDENTIFY screen for the selected detector is displayed.
Broadband CW Identify screen
The Broadband CW Identify screen shows a scrolling display of received broadband signal 
strength against time.
       The time scale can be changed using the Zoom In and Zoom Out on-screen buttons. 
This increases or decreases the rate at which the display scrolls.
The audio output in this mode is broadband AM (Amplitude Modulation).
       Alarm thresholds remain active in this mode and can be adjusted using the up and 
Down controls. 
When the alarm threshold is exceeded the appropriate alarm icon is displayed in the top right hand 
corner of the display and an entry is made in the EVENT LOG.
time
signal strength
alarm threshold