Davis Instruments DWW6351 Manuale Utente

Pagina di 31
Weather Data Specifications
49
Weather Data Specifications
Note: 
The following weather data specifications are listed as they are displayed on the 
console.
Weather Data Specifications
Variable
Resolution
Range
Nominal 
Accuracy (+/-)
Wind Direction
1
0 to 360
3
Compass Rose
22.5
16 compass pts.
0.13 compass 
pt.
Wind Speed
1 mph;
1 kt;
0.1 m/s;
1 km/h
2 to 150 mph;
2 to 130 kts
3 to 241 km/h,
 1 to 67 m/s
greater of
 2 mph/kts; 
1 m/s; 
3 km/h 
or 5%
Inside Temperature
0.1
F; 
0.1
C
+32
 to +140F; 
0 to +60
C
1
F; 
0.5
C
Outside 
Temperature
*
0.1
F;
0.1
C
-40
 to +150F;
-40
 to +65C
1
F;
0.5
C
Inside Humidity
1%
0 to 100%
3% RH; 
4% above 90%
Outside Humidity
1%
0 to 100%
3% RH; 
4% above 90%
Barometric 
Pressure**
0.01'' Hg;
0.1 mm Hg;
0.1 hPa;
0.1 mb
26'' to 32'' Hg; 
660 to 810 mm Hg;
880 to 1080 hPa; 
880 to 1080 mb
***
0.03'' Hg;
0.8 mm Hg 
1.0 hPa;
1.0 mb
Barometric Trend 
(3 hour)
Change Rates
Rapidly: 
.06'' Hg; 
1.5 mm Hg; 2 hPa; 2 mb
Slowly: 
.02'' Hg; 
0.5 mm Hg; 0.7 hPa; 0.7 mb
5 Arrow Positions: 
Rising Rapidly
Rising Slowly
Steady
Falling Slowly
Falling Rapidly
Dew Point)
1
F; 1C
-105
 to +130F; 
-76
 to +54C
3
F; 1.5C
Heat Index
1
F; 1C
-40
to +165F; 
-40
 to +74 C
3
F (1.5C)
Wind Chill
1
F; 1C
-110
 to +135F
-79
 to +57C
2
F;1C
*
Outside temperature accuracy is based on the temperature sensor itself and not on the sensor and the passive shielding 
together. The solar radiation induced error for the radiation shield: +4
F (2C) at solar noon with the wind speed at less than 
or equal to 2 mph (1 ms); The higher the wind speed, the less solar radiation induced error.
**