Wireless Repeater
Network Installation (Multiple Transmitters)
If you have two or more transmitters in your network, follow the instructions 
as if for a multiple repeater installation. Before you apply power to test your 
chosen locations, set unique ID codes for each transmitter and then set the clos-
est repeater to each transmitter to listen to that transmitter. 
Note: Each transmitter in your network must have a different ID code so that its signal remains       
distinct and identifiable throughout the network. See your Wireless Weather Station or the    
appropriate DavisTalk™compatible product manual for instructions on how to set the         
Transmitter and Receiver ID codes.
There are a number of ways you can configure your network. The only rule is 
that each transmitter’s data should only enter the network at one point,  
through one repeater. No two repeaters should be set to listen to the same 
transmitter directly.
Multiple T
ransmitter Network
You can set one repeater to listen to up to eight transmitters directly, and 
then re-transmit those signals to your consoles. To set the repeater to lis-
ten to each transmitter, flip the appropriate dip-switches on the repeater. 
M
ULTIPLE
 T
RANSMITTER
 N
ETWORK
In the diagram above, the Repeater/Transmitter ID dip-switches would 
have #1, #2, #3, and #4 set to ON, and the rest set to OFF. 
The Repeater’s ID Code dip-switches, on the other hand, would simply 
be set to default ID Code A (OFF, OFF, OFF) because the repeater in the 