Indyme Solutions Inc CB932 Manuale Utente

Pagina di 7
 
 
Technical Document 
430673-02 
Rev. G 
Indyme Solutions, Inc. 8295 Aero Place  San Diego, CA 92123 USA                      +1.858.268.0717  +1.800.829.6141 
 
Page 1 of 7 
 
CB932 Wireless Help Button 
Programming and Installation Instructions
 
 
Introduction 
The CB932 is a member of the Global Solutions Family. Indyme GSF 
products operate in the 800MHz – 900MHz frequency spectrum. The 
CB932 is a 1-button, GSF help button designed for use at customer 
service or sales floor locations. GSF Help Buttons are designed to 
communicate with a GSF Access Point. GSF products are not 
compatible with legacy devices. 
 
 
Hardware 
 
(2) #6 x 3/4” Phillips screw 
 
(2) #6 plastic wall anchor 
 
(2) strips, double sided adhesive 
 
(1) package alcohol swap 
 
(2) AA alkaline battery 
 
Programming Parameters 
GSF products MUST be properly programmed to establish communication. Programming parameters MUST 
match your configuration. The default settings are for testing purposes only and should not be used.  Failure 
to properly program your help button and access point will prevent your devices from working. 
 
GSF Help buttons have three primary programming parameters; Netcode, Address and Operating Mode. 
These MUST be programmed in the correct order to establish communication and ensure proper operation. 
Identify the parameters for your configuration before you begin programming.  
Using the programming instructions below set the following parameters in order. 
    
 
Netcode – unique identification code for the installation environment. 
 
Address – alarm number associated with a control unit alarm event. 
 
Operating Mode – defines how the help button will respond when activated. 
 
Programming a help button requires a series of button presses. The specific buttons vary by device type. 
On the CB932, SET is the “large button in the middle” and RESET is “the black outer cover”. The 
assurance LED is red and is located BEHIND to the SET button. This LED will flash during programming 
to indicate your progress. 
Netcode 
*00000001 
Address 
*0001 
Operating Mode 
*1 
* Default parameters are for testing purposes only. 
CB932 
RESET 
SET