Chamberlain Wireless Products Inc. OPB3 Manuale Utente

Pagina di 2
RELAY HOLD MODE
      
                                ULTRA RX 900-3
      
                             3 BUTTON ACCESS
POWER SAVE MODE
- 2 -
- 3 -
TEACHING A 3 BUTTON ACCESS TO AN ULTRA RX 900-3
ERASING THE MEMORY OF THE ULTRX 900-3
+   -
POWER
Pin 1 and 2 for 10 – 24 VAC 
Pin 1 and 3 for 10 – 24 VDC 
CONNECT THE ULTRA RX 900-3
OUTPUT TIMING
To place the Ultra RX 900-3 in Learn Mode:
 
Disconnect the power and wait at least 5 seconds. 
 
Reapply the power.  (The LED will illuminate until the Learn period has expired.
When the Learn period has expired, the Ultra RX 900-3 will buzz.) 
 
Within 10 seconds, press the learn button on the 3 Button Access unit. 
 
You will hear the RX 900-3 buzz and the 3 Button Access will sound a tone 
indicating the units have learned successfully. 
 
If you have additional 3 Button Access units, they can each be taught within 10 
seconds of each other or later by repeating this process.  If a 3 Button Access
unit was newly taught, the LED on the RX 900-3 will blink 3 times slowly.  If NO 
new units were taught the LED will display 4 blinks, 4 times. 
 
Once you are done teaching 3 Button Access units, wait 10 seconds for the 
Ultra RX 900-3 to leave learn mode.  The unit will buzz indicating the Learn
period is over and the units are ready to use. 
RELAY 1
Timing modes are determined utilizing the dipswitch located inside the unit.  This can be 
accessed by removing the 1 screw on the bottom of the unit.
RELAY 2
RELAY 3
The 3 Button Access is ONLY compatible with the Ultra RX 900-3.  Up to 8 3 Button 
Access units can be taught to 1 Ultra RX 900-3. 
 
NOTE: ONLY 1 Ultra RX 900-3 can be taught to 3 Button Access units.  A 3 Button 
Access CANNOT be used to control multiple Ultra RX 900-3 units.  
 
Install 4 ‘AA’ batteries into the 3 Button Access.  Lithium are preferred in cold climates.
Button 1 (GREEN) operates Relay 1 
Button 2 (WHITE) operates Relay 2 
Button 3 (RED) operates Relay 3 and releases Relays 1 and 2 
 
To reduce the power consumption of the Ultra RX 900-3, dipswitch 7 should be 
on.  This will not take effect until a button is pressed on EACH of the learned 3
Button Access units. 
With dipswitch 8 turned ON, the Ultra RX 900-3 will hold a relay, corresponding 
to the correct button pressed on the 3 Button Access unit, until the button is
released. 
Remove the screw on the back of the unit.
Press and hold the LEARN button until the LED double blinks, 3 times.
o  The RX 900 Unit has 3 Relays: 
•  Relay 1: 
 
Pin 11 – Common 
 
Pin 12 – Ch 1 Normal Open 
 
Pin 13 - Ch 1 Normal Closed 
 
•  Relay 2: 
 
Pin 8 – Common 
 
Pin 9 – Ch 2 Normal Open
 
 
Pin 10 - Ch 2 Normal Closed
 
 
•  Relay 3: 
 
Pin 6 – Common 
 
Pin 7 – Ch 3 Normal Open 
 
Pin 5 - Ch 3 Normal Closed 
 
RELAY OUTPUTS
OPB3
Patents Pending
4/3/2007