Chamberlain Wireless Products Inc. RX900 Manuale Utente
Carton Inventory
Overview
The Ultra RX - Extreme Range Receiver has a
10-24Vac/Vdc operation with low power consumption
(150 ua). The Receiver has 4 Channels, 2 Transistors
and 2 Relays. The Receiver can control up to
4 devices.
10-24Vac/Vdc operation with low power consumption
(150 ua). The Receiver has 4 Channels, 2 Transistors
and 2 Relays. The Receiver can control up to
4 devices.
1
Receiver
Model ULTRX900R
Ultra RX - Extreme Range Receiver
Setup
1 3
2
4 5 6 7 8 9 10
11
12 13
10-24 Vac
1 3
2
4 5 6 7 8 9 10
11
12 13
-
+
10-24 Vdc
NOTE: Polarity does not matter.
Power Connections
Relay Outputs
The Receiver has 2 Relays and 2 Transistor (Open
Collector) Outputs to control up to 4 devices.
Higher Amperage (10 amp) applications that are
directly controlled, should use Relay Channels 1
and 2.
Collector) Outputs to control up to 4 devices.
Higher Amperage (10 amp) applications that are
directly controlled, should use Relay Channels 1
and 2.
Relay 1:
11: Common
12: Ch 1 Normal Open
13: Ch 1 Normal Closed
11: Common
12: Ch 1 Normal Open
13: Ch 1 Normal Closed
1 3
2
4 5 6 7 8 9 10
11
12 13
Relay 2:
8: Common
9: Ch 2 Normal Open
10: Ch 2 Normal Closed
8: Common
9: Ch 2 Normal Open
10: Ch 2 Normal Closed
Lower Amperage (500 ma or lower) applications that
are indirectly controlled, should use Transistor Output
Channels 3 and 4.
are indirectly controlled, should use Transistor Output
Channels 3 and 4.
Channel 3:
Terminal 6
Terminal 6
Channel 4:
Terminal 4
Terminal 4
1 3
2
4 5 6 7 8 9 10
11
12 13
1 3
2
4 5 6 7 8 9 10
11
12 13
1 3
2
4 5 6 7 8 9 10
11
12 13
Dipswitch Settings
NOTE: If using the Receiver with a Gate Control Unit
(GCU) proceed to Program with Gate Control Unit
(GCU).
(GCU) proceed to Program with Gate Control Unit
(GCU).
NOTE: The Dipswitches on the
Receiver can be accessed by
removing the screw on the
bottom of the Receiver.
Receiver can be accessed by
removing the screw on the
bottom of the Receiver.
Ensure the Receiver does
not have power. Set
Dipswitch #1 to the ON
position.
not have power. Set
Dipswitch #1 to the ON
position.
NOTE: These steps apply only if more than one
Receiver is being used.
Receiver is being used.
Step 1: Ensure the
Receiver does not have
power. Set Dipswitch #1 to
the ON position in each
Receiver.
Receiver does not have
power. Set Dipswitch #1 to
the ON position in each
Receiver.
Step 2: Set the Identity of each additional Receiver
by changing the Dipswitches as shown in the chart
below.
by changing the Dipswitches as shown in the chart
below.
Receiver ID
Switch #2
Switch #3
2
ON
OFF
3
OFF
ON
4
ON
ON
Additional Receivers
NOTE: Do not connect power until instructed to do so.