Glossary
Automatic Door
Deactivation
In automatic door applications (doors that open via a motion sensor or push
paddle), the LC unit can deactivate this feature when a Tag enters a
monitored zone’s Tx Activation Field.
Delayed Egress Circuitry
A feature of the Accutech 3101 Magnetic Lock that, due to fire and life
safety codes, allows free egress through a door after 15 seconds of constant
force. In the event of a fire alarm, the Delayed Egress Circuitry is disabled.
Double conditioning
A characteristic of a zone that requires two conditions to be met (such as
Tag detection and PIR detection) before an alarm is generated.
Tag detection and PIR detection) before an alarm is generated.
Egress alarm
An alarm condition that occurs when a Tag is in the Tx Activation Field
and a door is opened (or PIR detection).
and a door is opened (or PIR detection).
Elevator
Deactivation Circuitry
Deactivation Circuitry
Circuitry that deactivates an elevator’s call button(s) when a Tag is a
monitored elevator zone.
monitored elevator zone.
Escort Function
A function of the Keypad used to escort Tags through a monitored zone
without triggering alarms.
without triggering alarms.
Fire Panel Interface
(FPI)
(FPI)
A FPI ties Accutech Security System components into the facility’s fire
panel. Required if the system includes Magnetic Locks and/or Elevator
Deactivation Circuitry. In the event of a fire, Magnetic Locks and Elevator
Deactivation Circuitry are disabled. However, if there is still power to the
system, the alarms will still sound.
panel. Required if the system includes Magnetic Locks and/or Elevator
Deactivation Circuitry. In the event of a fire, Magnetic Locks and Elevator
Deactivation Circuitry are disabled. However, if there is still power to the
system, the alarms will still sound.
Graphic Display Panel
(GDP)
(GDP)
A display panel, which provides staff with a representation of the floor
being monitored. GDPs are custom-made to a facility’s floor plan and
notify staff when an alarm condition occurs in a monitored zone through a
piezo buzzer and alarm-specific LEDs.
being monitored. GDPs are custom-made to a facility’s floor plan and
notify staff when an alarm condition occurs in a monitored zone through a
piezo buzzer and alarm-specific LEDs.
Keypad
A Keypad is used to reset zone equipment once an alarm has been
addressed (Keypad Reset) or to escort Tags through a monitored zone
without triggering alarms (Keypad Escort). The Keypad is also capable of
providing visual indicators for Tag detection, alarms, and escort time.
addressed (Keypad Reset) or to escort Tags through a monitored zone
without triggering alarms (Keypad Escort). The Keypad is also capable of
providing visual indicators for Tag detection, alarms, and escort time.
Keypad Reset
A feature of the Keypad that is used to reset zone equipment after an alarm
has been addressed.
has been addressed.
LED Tag
A Tag designed to verify proper zone coverage (without causing alarms)
during installation, adjustment, or testing of a monitored zone.
during installation, adjustment, or testing of a monitored zone.