HID Global Corporation 5553 Manuale Utente

Pagina di 144
 
HF Multi ISO RFID Reader User Manual, Firmware V1.4 
 
1508-USM-00-0-04 
 
5.4.4  Special function (EAS,) AFI 
Special Functions (EAS) and Family Code/Application Identifier are additional features. For more 
information refer to the ICODE® manual. 
5.4.5  User data 
All other blocks are free for use and can be changed according the state of the write access 
conditions. 
5.5  ICODE EPC 
ICODE EPC labels data is stored in a OTP memory. Its capacity is 136 bits organized in 17 blocks 
consisting of 1 bytes each. All MSB of the different fields (EPC, CRC16, Destroy Code) are located 
at the lowest block address. 
5.5.1  Memory organization 
Page address 
Byte 
14h – 16h 
Destroy Code 
12h – 13h 
CRC 16 
00h – 11h 
EPC 
5.5.2  Serial number 
The serial number of a label is defined within the EPC blocks. 
5.5.3  Read Block 
It is not possible to read a block with the read block 'rb' command. 
5.5.4  Write Block 
It is possible to write the EPC data (12 bytes) with the write block 'wb' command using block 
address 00h. 
5.6  ICODE UID 
The memory has a capacity of 192 bits and is organized in 24 blocks, consisting of 1 byte each. All 
MSB of the different fields (UD, UD CRC, CRC16, Destroy Code) are located at the lowest block 
address. 
5.6.1  Memory organization 
Page address 
Access Condition 
Description 
21h – 23h 
OTP 
Destroy Code 
19h - 20h 
OTP 
CRC16 
14h – 18h 
RO 
UID 
12h – 13h 
R/W 
UD CRC16 
00h – 11h 
R/W 
User data (UD) 
 
August 2010 
 
Page 121 of 144 
© 2005-2010 HID Global Corporation.  All rights reserved.