HID Global Corporation 5553 Manuale Utente
1508-USM-00-0-04
HF Multi ISO RFID Reader User Manual, Firmware V1.4
2.1.2 Binary Protocol
This protocol is designed for industrial applications with synchronization and frame checking. An
addressing byte for party line (master/slave, multi-drop) is also included.
addressing byte for party line (master/slave, multi-drop) is also included.
The protocol usually requires a device driver. Data is transmitted in binary mode. The reader uses
an internal binary watchdog timer to ensure correct framing.
an internal binary watchdog timer to ensure correct framing.
STX
Station ID
Length
Data
BCC
ETX
1 byte
1 byte
1 byte
Variable length
1 byte
1 byte
The binary frame version 2 is only sent to the host. It is implemented to give extended information to
the host. Version 2 must be enabled in the Protocol configuration 2 register.
the host. Version 2 must be enabled in the Protocol configuration 2 register.
STX
Station ID
Length
Flags
Data
BCC
ETX
1 byte
1 byte
1 byte
1 byte
Variable length
1 byte
1 byte
2.1.2.1
STX
Start of transmission (02h)
2.1.2.2
Station ID
Unique ID of the station
00h:
Reserved for the bus master. Readers send response to this device ID.
FFh:
Broadcast message. All devices will execute the command and send their response.
2.1.2.3
Length
Length defines the length of the data block, including the flag byte, if binary protocol version 2 is
activated. If length is set to zero, 256 data bytes are transmitted. The reader module only can send
256 data bytes, but cannot receive commands with 256 bytes.
activated. If length is set to zero, 256 data bytes are transmitted. The reader module only can send
256 data bytes, but cannot receive commands with 256 bytes.
2.1.2.4
Flags
The flag byte gives additional information to the host.
Bit 3 – Bit 7
Bit 1 – Bit 2
Bit 0
RFU
Leading Character Info
Error State
Error State
If cleared, the command was processed successfully. If set, an error occurred.
Leading Character Info
Bit 1 & 2 defines how to interpret the data in the binary frame.
Bit 2
Bit 1
Description
0
0
No leading character available, all values are hexadecimal.
0
1
The data contains one leading character.
1
0
All data bytes are characters.
1 1 RFU
Page 20 of 144
August 2010
© 2005-2010 HID Global Corporation. All rights reserved.