HID Global Corporation 5553 Manuale Utente

Pagina di 144
 
 
 
1508-USM-00-0-04 
 
HF Multi ISO RFID Reader User Manual, Firmware V1.4 
 
2.2.5  BAUD, Baud Rate Control Register (0Ch) 
Default = 00h 
The baud rate register defines the communication speed of the reader device. 
Baud rate register 
Bit 7  
Bit 6 
Bit 5 
Bit 4 
Bit 3 
Bit 2 
Bit 1 
Bit 0  
RFU RFU RFU RFU RFU BS2  BS1  BS0 
This register defines the baud rate of the device.  
BS2 
BS1 
BS0 
Baud rate 
9600 baud (default) 
0 0 1  19200 
baud 
0 1 0  38400 
baud 
0 1 1  57600 
baud 
1 0 0  115200 
baud 
230400 baud (depends on the used interface chip) 
460800 baud (depends on the used interface chip) 
With the high baud rates (230400 and 460800 baud), proper operation depends on the interface 
chip used. Please note that some of the interface chips available do not support these high baud 
rates. 
The following table describes the exact baud rates used by the reader. 
Baud rate 
Exact baud rate 
Difference 
9600 baud 
9603 baud 
0.03 % 
19200 baud 
19207 baud 
0.04 % 
38400 baud 
38305 baud 
-0.25 % 
57600 baud 
57458 baud 
-0.25 % 
115200 baud 
114915 baud 
-0.25 % 
230400 baud 
233793 baud 
1.47 % 
460800 baud 
452000 baud 
-1.91 % 
The following table describes the communication settings. 
Description 
8 data bits 
No parity bit 
1 stop bit 
No flow control 
 
2.2.5.1 
CF Card Version 
The Baud rate of the CF Card version is limited to 115200 baud. 230400 and 460800 are not 
supported. 
Page 28 of 144 
 