HID Global Corporation 5553 Manuale Utente

Pagina di 144
 
HF Multi ISO RFID Reader User Manual, Firmware V1.4 
 
1508-USM-00-0-04 
Option 
See High-speed select, page 45 for a full description of this byte. 
Reset Off 
The length of time the field is switched off 
Reset Recovery 
The time for the field to stabilize after being switched on 
Wait 
The length of time in mS * 4 the reader will search for tags (19h = 25 * 4 = 100mS) 
Note: A zero wait time is not supported by the reader. 
2.3.1.9 
Lock Block 
This command locks a block permanently. Only SR176 and ISO 15693 tags are supported. 
 
Command 
Command 
Data 
'k' 
Block address (1 byte) 
 
Answer 
Answer 
Description 
Data 
'K' + page address 
'F' 
Error: Lock failure 
'N' 
Error: No tag in field  [addressed tag not present or not responding] 
'O' 
Error: Operation mode failure   [tag is neither SR176 or ISO 15693 compliant] 
'X' 
Error: Block already locked 
 
Example 
Command 
Description 
k05 K05 
Lock block 05. 
2.3.1.9.1 
Apply settings 
After locking a block permanently, the tag needs to be selected for the settings to apply. 
 
 
August 2010 
 
Page 49 of 144 
© 2005-2010 HID Global Corporation.  All rights reserved.