HID Global Corporation 5553 Manuale Utente
HF Multi ISO RFID Reader User Manual, Firmware V1.4
1508-USM-00-0-04
Option
See High-speed select, page 45 for a full description of this byte.
Reset Off
The length of time the field is switched off
Reset Recovery
The time for the field to stabilize after being switched on
Wait
The length of time in mS * 4 the reader will search for tags (19h = 25 * 4 = 100mS)
Note: A zero wait time is not supported by the reader.
2.3.1.9
Lock Block
This command locks a block permanently. Only SR176 and ISO 15693 tags are supported.
Command
Command
Data
'k'
Block address (1 byte)
Answer
Answer
Description
Data
'K' + page address
'F'
Error: Lock failure
'N'
Error: No tag in field [addressed tag not present or not responding]
'O'
Error: Operation mode failure [tag is neither SR176 or ISO 15693 compliant]
'X'
Error: Block already locked
Example
Command
Description
k05 K05
Lock block 05.
2.3.1.9.1
Apply settings
After locking a block permanently, the tag needs to be selected for the settings to apply.
August 2010
Page 49 of 144
© 2005-2010 HID Global Corporation. All rights reserved.