HID Global Corporation 5553 Manuale Utente

Pagina di 144
 
 
 
1508-USM-00-0-04 
 
HF Multi ISO RFID Reader User Manual, Firmware V1.4 
 
2.3.1.31  Write EEPROM 
Writes to the internal reader EEPROM. It contains all start-up parameters and the device ID. 
Changes to the start-up settings will only go into effect after a reset of the device. 
Command 
Command 
Data 
'wp' 
Address (1 byte), valid range 0Ah - EFh 
Data (1 byte) 
Answer 
Answer 
Description 
Data 
EEPROM data (1 byte) 
'F' 
Error: Read after write failure 
'R' 
Error: Out of range failure  [entered address exceeds the address range] 
Example 
Command 
Description 
wp0A01 
Set EEPROM address 0A (Station ID) to 01h 
 
2.3.1.32  Reset 
This command executes a power on (software) reset. New configuration settings will be loaded. It 
resets all tags in the antenna field. 
Command 
Command 
Data 
'x' None 
Answer 
Answer 
Description 
‘MultiISO  1.2' + <CR> + <LF> 
ASCII Mode 
None Binary 
Mode 
2.3.1.32.1  Disable Start-up Message 
If the start-up message is disabled in the protocol configuration 2 register,  the ASCII mode does 
not respond with the version of the reader. 
2.3.1.32.2  Reset Timing 
The power up timing depends on environmental conditions such as voltage ramp up. For 
handheld devices the timing can vary based on the charge state of the battery. 