Receiving the answer 
The reader switches to receiving mode automatically after data is sent. If no data is detected the 
reader returns the error 'N' no tag in field. If the time-out value (registers 10h and 11h) is too short, 
the reader will abort the tag detection process before the answer is received. Increase the time-out 
value and the communication will work. 
Answer = 'C' - Collision 
If a collision is detected, (more than one tag in the field) the anti-collision sequence is required 
before accessing the tags. Anti-collision is a complex procedure. The use of Multitag List and 
Multitag select is recommended – see Multi-Tag Selection / List, pag50
Answer = Uplink length + Data 
This would be the expected response 
Examples for ISO14443-A tags (in ASCII mode) 
Select sequence for a single tag in the field – refer to ISO14443-3 specification for details 
Command 
Answer 
Description 
t 01 E3 26 
02 0400 
7 bit (E)  REQA (code = 0x26) 
Answer = ATQA (04 00) 
t 02 03 93 20 
07 0481635640F480 
Get full serial number (code=0x93, 
NVB=0x20).  Answer = serial No 
t 09 0F 93 70 0481635640F480  01 88 
Select card with UID 0481635640F480 
Answer = SAK 
t 02 0F 30 04 
10 010203... 
Read block 4: (after login) 
command code is 0x30 
 
2.3.5.2 
Transmit / Receive mode 
Command 
Data 
Transmit/Receive mode 
Downlink length (1 byte) = 0 
Downlink length new (1 byte) 
Option byte (1 byte) 
Transmit byte (1 byte) 
Receive byte (1 byte) 
CRC Preset LSB (1 byte) 
CRC Preset MSB (1 byte) 
Data (n bytes) 
't' 
In Transmit / Receive mode, data is sent to the tag in two steps. Furthermore, data is sent and 
received separately with different options.   
This mode only supports ISO 14443 up to part 1-3.  (For example Mifare Ultralite tags) 
2.3.5.2.1 
Downlink length 
The downlink length must be zero to activate the Transmit / Receive Mode. 
2.3.5.2.2 
Downlink length new 
The downlink length includes only the data length. 