Edge is the next evolution in access control hardware solutions. A true IP solution that meets the demands of open architecture, IP-centric 
environments, Edge provides fully distributed intelligence and decision making right to the door, leveraging the IT infrastructure to the 
maximum extent possible. Wire the Edge device to Hi-O interface modules to provide connectivity to electronic door components and 
access control readers.
Hi-O involves devices with built-in intelligence and a CANbus that links all the devices together. Hi-O CANbus data traffic can be password 
protected and encrypted, or both. Each Hi-O device (such as the push plate, electric strike, card reader, door operator) is connected to the 
CANbus by a single, four-wire cable. Two of the wires supply power and the other two are used for data communication.
Specifications
CONNECTION
PARAMETER
CONDITIONS
VALUE
OPERATING 
TEMPERTURE
CABLE LENGTH
PoE Power 
(input)
Voltage - Nominal
-
48 VDC
32° - 122°F
(0° - 50° C)
Hi-O CAN Bus 
= 30 ft (9 m) 
-  22 AWG ● 0.65mm ● 0.33mm
2
 
= 75 ft (23 m) 
-  18 AWG ● 1.02mm ● 0.82mm
2
RJ45 
= 328 ft (100 m) 
-  Category 5 K
Current - Normal Standby 
Condition (NSC)
CAN PWR - not loaded
75 mA
Current - Maximum
CAN PWR - max load
275 mA
 +DC (input)
Voltage
-
12 VDC - 24 VDC
Current - Normal Standby 
Condition (NSC)
12 VDC
CAN PWR disconnected
190 mA
Current - Normal Standby 
Condition (NSC)
24 VDC
CAN PWR disconnected
110 mA
Current - Maximum
12 VDC
2.2 A
Current - Maximum
24 VDC
2.1 A
CAN PWR 
(output)
Voltage - Nominal
PoE
24 VDC
Current - Maximum
PoE
300 mA
Voltage - Nominal
+ DC
+ DC
Current - Maximum
+ DC
2 Amp - AUX limited
Edge
EdgeReader® and EdgePlus®
Models: EH400, EHR40, EHRP40, EH400-K
 ER40C, ERP40C
I
nstallatIon
 G
uIde
82000-920, Rev A.1
December 10, 2009
© 2009 HID Global Corporation.  All rights reserved.
15370 Barranca Parkway
Irvine, CA 92618-2215
USA
DRAFT