HID Global Corporation ICLASSU90 Manuale Utente

Pagina di 6
iCLASS SE
 INSTALLATION GUIDE
2
PLT-01545, A.0
U90 (U90.915 & U90.865)
© 2014 HID Global Corporation/ASSA ABLOY AB.  All rights reserved.
Specifications
Parts List 
P
arts
1 - iCLASS Reader 
1 - Installation Guide
2 - #6-32 x .375” Phillips machine screws 
2 - #6-32 x .375” Spanner security screw, anti-tamper 
2 - 7-pin Terminal connectors 
1 - 10-pin Terminal connector
1 - Mounting Gasket
1 - Back Box
r
ecommended
• Cable, 5-9 conductor (Wiegand or clock-and-data)
• Linear DC Power supply
• Metal or plastic junction box 
• Security Tool (for anti-tamper screw) HID 04-0001-03
• Drill with various bits for mounting hardware
• Mounting Hardware
UL Reference Number Deciphering
x
1
  Reader Colors:
 
K = Black
x
Wiring: 
 
T = Terminal
x
Communications: N = No Module 
                            
PRODUCT BASE PART 
NUMBER
INPUT 
VOLTAGE (VDC)
CURRENT
OPERATING 
TEMPERATURE
CABLE LENGTH
UL REF 
NUMBER
Standby 
AVG
1
Max 
AVG
2
PEAK
3
U90
960N
12 VDC
320mA 400mA 1.0 A
-30° to 150° F
(-35° to 65° C)
Power Supply Lines
40 ft (12 m)  - 22 AWG
100 ft (30 m)  - 18 AWG
Communication Lines
Wiegand / Clock-and-Data
500 ft (152 m) - 22 AWG
RS-485
4,000 ft (1,219 m) - 24 AWG
U90A
x
1
x
2
x
3
24 VDC
160mA 200mA 0.5 A
Standby AVG - RMS current draw without a card in the RF field.
Maximum AVG - RMS current draw during continuous card reads. Not evaluated by UL.
Peak - highest instantaneous current draw during RF communication.
Relays
Three (3) each dry relays for operating external audio and visual indicators. Not to be used for Access Control. Rated 30VDC, 2A 
resistive.