HID Global Corporation IDENTICLASSA Manuale Utente

Pagina di 24
 
 
identiCLASS Developer Tool Kit User Guide 
Configuration 
The standard default configuration settings for identiCLASS readers are as follows: 
 
Reader Core 
(DG3300A00)     
Single antenna, ID3 
Reader Board   (DG3500A00)     
Integrated antenna enabled, 2x External antenna’s,
     both 
ID3 
Note: These configuration settings can be altered using the identiCLASS software configuration 
tool (refer to the identiCLASS Developer Tool Kit software configuration tool user guide), or the 
identiCLASS production configuration tool (refer to the identiCLASS production configuration 
tool user guide) 
8.1 
Modulation Index (MI) 
The Modulation Index has to be within the range defined in the standard to which your 
equipment must conform. 
8.2 
Rx Threshold 
The Rx Threshold can be adjusted. In situations where there is background RF noise, the Rx 
Threshold can be increased so that the receiver will not be switched on by the noise. 
8.3 
Rx Gain 
The Rx Gain can be adjusted. It may be desirable to reduce the Rx Gain when there is 
background RF noise. 
8.4 
Changing these parameters 
To adjust any of these parameters, do the following: 
1. Run 
the 
Software Configuration Tool
2. Click 
the 
Device Settings tab. 
 
October 2010 
 
Page 19 of 24 
HID GLOBAL CONFIDENTIAL AND PROPRIETARY INFORMATION.  Use and disclosure of this information is strictly 
restricted by the terms of a non-disclosure agreement with HID Global Corporation.  If you have received this information and 
are not an intended recipient or are not subject to or do not agree to be bound by the terms of the non-disclosure agreement, 
please immediately return this document to HID Global Corporation, 15370 Barranca Pkwy, Irvine, CA 92618-3106..