identiCLASS Developer Tool Kit User Guide 
 
 
Configuration 
It may be helpful in certain situations to adjust the following parameters using the Software 
Configuration Tool. 
8.1 
Modulation Index (MI) 
The Modulation Index has to be within the range defined in the standard to which your 
equipment must conform. 
8.2 
Rx Threshold 
The Rx Threshold can be adjusted. In situations where there is background RF noise, the the 
Rx Threshold can be increased so that the receiver will not be switched on by the noise. 
8.3 
Rx Gain 
The Rx Gain can be adjusted. It may be desirable to reduce the Rx Gain when there is 
background RF noise. 
8.4 
Changing these parameters 
To adjust any of these parameters, do the following: 
1.  Run the Software Configuration Tool. 
2.  Click on the Device Settings tab. 
 
3.  If you have more than one reader connected to the computer, choose it in the drop-
down box at the top of the screen. 
4.  Choose the standard for which you want to apply these settings by choosing one of 
the tabs on the left. 
5.  If you have more than one antenna connected to the reader, choose the antenna 
whose settings you want to configure: Antenna 0, Antenna 1, Antenna 2. 
6.  Set values according to standard configuration for: in this drop-down box 
choose the type of antenna you are configuring: