HID Global Corporation SE3200 Manuale Utente

Pagina di 42
OEM50 
SE32XX 
P1 Connector 
 
Pin 1 
Open Output 
SE32XX does not have a similar signal 
Pin 2 
Ground 
Same as P301 pin 2, signal Ground 
Pin 3 
Wiegand Data1 
Wiegand data output is per the SIA AC-01 
(1996.10) specification, except Voh is 3.3VDC 
max, and not 4.0 to 5.5 VDC 
OEM50 is inverted logic 
Pin 4 
Wiegand Data0 
Wiegand data output is per the SIA AC-01 
(1996.10) specification, except Voh is 3.3VDC 
max, and not 4.0 to 5.5 VDC 
OEM50 is inverted logic 
Pin 5 
Power On Reset 
Same as P701 pin 3 /Reset function 
Pin 6 
Hold 
Similar to P701 pin 4, however /Hold is low active 
 
2.5.2  OEM75 
The SE32XX module I/O is directly pin-for-pin compatible with the OEM75. 
The OEM75 antennas are incompatible with the SE32XX module.  
ULPM average current remains the same while peak current is higher for the SE32XX 
module. 
2.5.3  eProx Lock Module 
The eProx
®
 Lock connector is the same as the SE32XX connector P701.  
CAUTION: The connections between the SE32XX and the eProx Lock modules are 
reversed. 
A straight-thru cable will not work.  Twist the cable 180 degrees to ensure that Pin 1 on one 
module correctly mates with Pin 1 on the other module. 
The two-wire 125 kHz antenna for the eProx Lock may not be interchangeable with an 
SE32XX Prox antenna.