Electrical Specifications 
5.1 
Maximum Ratings 
Stresses beyond those listed may cause permanent damage to the device. This is a stress 
rating and functional operation of the device at these or other conditions (beyond those 
indicated in the operational sections) is not implied. Exposure to absolute maximum rating 
conditions for extended periods may affect device reliability. 
Table 8: Maximum Ratings 
Operating Temperature 
-25°C to 65°C 
Storage Temperature 
-45°C to 85°C 
Maximum Operating Voltage 
10 VDC 
5.2 
Current Draw 
The following measurements were performed with a 50 Ohm load connected to the HF 
interface. In the case a real antenna is connected to the iCLASS SE Reader Module’s power, 
consumption changes depending on the presence of a transponder and its relative position to 
the antenna. For that reason, find guidance for changing power consumption for particular 
antennas in section 6 RF Interfaces. 
The power consumption is independent of the supply voltage, as the iCLASS SE Reader 
Module uses a linear regulation system. 
Table 9: Power Considerations 
Mode 
Parameter 
Min 
Typ 
Max 
Unit 
Normal Power Mode 
Polling for HF transponders 
in autonomous mode 
1
 
No Prox 
Average DC current at 20°C 
 
40 
 
mA 
Peak Current 
2
 at 20°C 
 
81 
 
mA 
Normal Power Mode 
Polling for Prox Credentials 
(HF deactivated) 
Average DC current at 20°C 
 
50 
 
mA 
Peak Current 
2
 at 20°C 
 
80 
 
mA 
Ultra Low Power Mode 
Average DC current at 20°C 
 
8.5 
 
µA 
Peak Current 
2
 at 20°C 
 
24 
 
µA 
1
 
Polling cycle includes ISO/IEC14443 Type A and Pico15693. Adding additional protocols to the polling cycle may 
vary the power consumption. 
2
 
When the carrier is turned on, the current consumption of the module may build to create the required magnetic 
field. The peak currents are also considered in the average current measurement.