Table 24: Electrical Characteristics 6500-101-03 
Parameter 
Measurement 
Frequency 
Typ 
Unit 
Number of turns 
 
89 
DC Resistance 
 
33 
Ω
 
SRF 
 
MHz 
Inductance 
1kHz 
800 
µH 
Impedance  
50kHz 
29+j248 
Ω
 
100kHz 
31+j489 
Ω
 
500kHz 
50+j2674 
Ω
 
7.4.3  Typical Read Ranges 
The measured read ranges are indications only. Read range varies due to transponder 
antenna size and quality, as well as environmental effects. 
Table 25: Typical Read Ranges 6500-101-03 Prox Antenna 
Transponder 
Modulation 
Scheme 
Typical Read 
Range [mm] 
HID Prox 
FSK 
40 
HID DuoProx II 
FSK 
60 
MIFARE / HID Prox 
Combo Card 
FSK 
60 
Indala Prox 
PSK 
55