HID Global Corporation SE3210 Manuale Utente

Pagina di 42
 
iCLASS SE Reader Module Hardware Developer Guide, SE3200-902, Rev B.0 
 
October 2012 
 
Page 13 of 42 
HID GLOBAL CONFIDENTIAL AND PROPRIETARY INFORMATION.  Use and disclosure of this information is strictly 
restricted by the terms of the end user license agreement with HID Global Corporation.  If you have received this information 
and are not an intended recipient or are not subject to or do not agree to be bound by the terms of the non-disclosure 
agreement, please immediately return this document to HID Global Corporation, 15370 Barranca Pkwy, Irvine, CA 92618-3106. 
 
2.4 
Peripheral Circuits 
The following section details recommended peripheral circuitry.  
2.4.1  External Pull-up Resistors 
External pull-up resistors may be required on the UART Tx and MOSI lines to prevent floating 
I/O anomalies. 
2.4.2  External Noise Filter  
If false card detections occur in Ultra Low Power mode, or the host has spectral noise, a line 
filter designed to block frequencies in the 10 KHz to 50 KHz range is beneficial when inline 
with the power line.  
2.4.3  Adding External LEDs and Beeper 
The Cathodes are connected through an external resistor to the RED or GREEN LED 
connector port signals. The OEM supplies current limiting resistors for modules.  
The value of these resistors depends on how much current is provided for the LEDs. 
Consider the combined voltage drop of the resistor and OEM75 output low voltage on these 
signal lines when selecting the LED brightness.  
2.5 
Transitioning from the OEM50, OEM75 and eProxL Modules 
Provided are suggestions for transitioning from the HID OEM50 and eProx Lock modules to 
the OEM75. 
2.5.1  OEM50 
If you are transitioning from an OEM50 – here are the differences. 
  The OEM50 connector is a 2 X 6 0.1" space pin header or PWB hole pattern. 
  The OEM50 has a two-wire interface to the antenna and the iCLASS SE 
Reader has a 2-wire interface for NPM and a 5-wire interface for ULPM 
applications. Therefore, it is possible that the OEM50 antenna will work with 
the SIO Processor Board in NPM. 
  The harness and signal changes to adapt the signals from the OEM50 2 X 6 
pattern to an OEM75 1 x 9 1.25mm pattern are the following. 
Note: The additional P2 for HSI and SPI interfaces are 1 x 8 1.25mm pattern. 
OEM50 
SE32XX 
P2 Connector 
 
Pin 1 
Exc Supply 
No signal on the SE32XX 
Pin 2 
Exc Return is not used 
No signal on the SE32XX 
Pin 3 
Serial Transmit 
Same as P301 pin 8 - UART Transmit 
Pin 4 
Serial Receive 
Same as P301 pin 7 - UART Receive 
Pin 5 
Vdd Return 
Same as P701 pin 2 - Battery Minus 
Pin 6 
Vdd +5VDC 
Same as P701 pin 1 - Battery Positive  
and 5VDC is a good supply voltage