HID Global Corporation 6042AA Manuale Utente

Pagina di 32
_________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618 USA TEL (949) 598-1600  (800) 237-7769  FAX (949) 598-1690
Web page – 
www.proxtrak.com
 –  ProxTrak Portal Reader Installation Procedure    6042-901-01 Rev 7              
26 of 32
   A
    B
   C
   D
   E
  F
   G
   H
   J
MiniProx
28/32
29/41
28/52
22/28
27/63
36/55
33/70
35/48
33/70
ProxPro
41/53
48/55
38/54
33/48
45/57
42/69
30/35
48/74
42/82
ProxPro+
51/187
96/119
74/99
92/122
77/87
145/23
102/103 88/120
165/240
MaxiTrak
29/32
22/32
26/34
24/31
34/58
31/40
22/39
31/42
48/64
Portal
94/265
103/146 111/117 75/88
118/150 117/185 84/96
116/187 139/146
Figure 4-2.  Interference Distances
11.  Environmental Radio Frequency Noise Test
The following is a description of a test (or measurements) to  be  completed to ensure that the portal is
able to interact with other RFID readers.
11.1 Required Equipment
 
Spectrum Analyzer (HP3585A)
 
“Standard” antenna  (MaxiTrak antenna) mounted on tripod with degree markings
11.2 Test Procedure
NOTE: This procedure should be performed during a normal work period, i.e. elevators or escalators
running, computer monitors running in their normal mode of operation, any access readers in the area
turned on etc.
Setup tripod in the center of the proposed unit location starting with the antenna oriented towards the 0
°
mark (see Figure 5-1) and approx. 42” above the floor.  Connect to the spectrum analyzer and setup
analyzer as follows:
1.  Set Scan Range from 80 kHz to 200 kHz
2.  Use 1 Meg ohm input impedance
3.  Set Resolution Bandwidth to 1 kHz
4.  Set Video Bandwidth to 3 kHz
Direction of travel
0 - degrees
90 - degrees
270 - degrees
Figure 5-1 Portal Orientation