PARTS INCLUDED 
SPECIFICATIONS 
• 1 
-
 
iCLASS Keypad Reader 
• 
Voltage Range:                  12VDC (10 - 16VDC). 
• 
1 - Installation Manual 
• 
Current:                             100mA avg / 220mA peak. 
• 
2 - 3.5mm x  .6 pitch x 12mm Phillips machine screws 
• 
Cable distance to Host:     500ft (152m) max – Wiegand. 
• 
3 - #6-32 x .375” Phillips self-tapping machine screws  
 
50ft (15m) max – RS-232.
 
• 
2 - #6 x 1.5” Phillips sheet metal screws  
 
4000ft (1216m) max – RS-485.
 
• 
1 - #6-32 x .375” Spanner security screw  
• 
Op. Temperature:            -31°F - +149°F (-35°C – +65°C) 
Recommended: 
• 
Open collector output: 
Sink – 40mA, source – 1mA. 
• 
Up to 10 wire splices * 
Standards:
 
 
• 
Cable, 9 conductor, 22AWG, shielded (Wiegand) 
• 
Cable , 6 conductor, 22AWG, shielded (Serial) 
• 
Read/Write* capability in ISO 1SO 15693-2 mode with HID 
iCLASS credentials. 
• 
Linear DC Power Supply 
• 
Metal or plastic junction box 
• 
Security Tool (for security screw) HID 04-0001-03 
• 
Read/Write* capability in ISO 1SO 14443-B mode with HID 
iCLASS 16KS. 
• 
Magnetic Tamper switch - Ademco 945T, Sentrol 
1038T, GRI 100T or 110T or Aleph DC-2531 
• 
Read capability of CSN/UID in ISO 1SO 14443-A1 mode 
with HID Mifare and other 3
rd
 party Mifare credentials. 
* RK40 available with 18” wire pigtail or 10-pos. removable 
screw terminal connector.  RWK400 includes 8-pos. and 10-
pos. removable screw terminal connectors. 
* RK40 is a read only, while RWK400 is a read/write unit. 
 
INSTALLATION  
 
1- Disassemble 
 
A.  Remove the screw at the bottom of the unit. 
B.  Lift the mounting plate out at the bottom side  
C.  Slide mounting plate down 
 
 
 
 
 
 
 
 
 
 
2- Install Tamper Switch 
An internal magnet provides tamper indication when used with a magnetic reed switch connected to an external alarm 
system.  Locate Switch behind the left side of the mounting plate, centered between the mounting holes. 
                              
 
       
 
Electrical Back Box 
Wall Surface