WLS Installation and Maintenance Manual 
Installation 
Geometrix
® 
Wireless Location System 
 
36 
Andrew Corporation Proprietary 
connections, a WLS WAN port cable failure or problems within the carrier T1 network.  Additional 
loopback tests should be performed at various locations along the T1 signal chain to isolate the 
fault.  The WAN test requires that personnel be located at the WLS site to add/remove loopback 
connectors.  If the test is run remotely (e.g. via telnet) the connection to the WLS is generally 
made via the WAN port, thus validating it’s operation and this test does not need to be run. 
 
Testing the WLS WAN port requires a female DB-25 loopback connector be put on the WLS’ rear 
DB-25 port.  The pinout and connections for the WLS loopback connector are shown below. 
 
15 - 17
14 - 16
13 – 19 - 21
10 – 18 - 23
9 - 12
2 - 3
15 - 17
14 - 16
13 – 19 - 21
10 – 18 - 23
9 - 12
2 - 3
 
Figure 2-14  WLS Loopback Connector 
2.10.10 
COM Port Test 
This test is optional.  It is not performed during the “All Tests” procedure.  This test performs a 
loopback test on the front-panel RS_232 serial port.  This test requires that access to the WLS 
under test is made via a local Ethernet or WAN port connection, and a RS-232 hardware 
loopback plug is installed on the serial port. 
 
 
An example of the test display is shown below. 
 
Enter your choice: 10 
 
COM PORT TEST: 
Test Result: PASS 
 
Press any key to continue. 
 
Failure of the COM port test failure indicates an internal WLS hardware fault.  The failed unit 
should be returned for repair. 
2.10.11 Alarm 
Contacts 
The alarm contact menu option provides a tool for manually opening and closing the WLS alarm 
relay contacts.  This is intended for use in NOC coordinated dry-contact alarm relay testing.  
An example of the display is shown below. 
 
Enter your choice: 11 
 
CHANGE ALARM RELAY OPERATION 
0 Normal Operation 
1 Force Alarm 
: 1 
Relay Forced into 'Alarm' position