Setting the Acquisition Code
An acquisition code is a unique code contained within the preamble of a transmitted message. Units search 
the air for messages that begin with a particular acquisition code. Messages without the correct code are 
treated as interference and are rejected by a unit. Messages with the correct code are accepted and 
processed. Acquisition codes serve to isolate units from each other, especially when several units operate in 
close proximity or at the same frequency in a multiple-sector or multi-cell environment. All units in the same 
network must have the same acquisition code in order to communicate with each other.
➧ 
To set the acquisition code
1.
From the Main Menu, select Radio Module Configuration and press 
Enter
. The Radio Module 
Configuration menu is displayed.
2.
Select Acquisition Code and press 
Enter
. The data field highlights.
3.
Type the Acquisition code (0-15).
4.
Press 
Enter
. The new setting is displayed in the "New" column.
5.
Select Reboot New RF Configuration and press 
Enter
. The unit reboots and the AWE 120-24 
Login menu is displayed. The unit now runs using the "Current" acquisition code for the amount of time 
specified by the Current Test Minutes.
6.
To save the current setting(s) to flash memory, log in, go to the Main Menu, and select Radio Module 
Configuration,
 Save Current Config to Flash. See 
. 
7.
Press 
Esc
 to exit to the Main Menu.
                             Radio Module Configuration
                                      New         Current        Flash
Station Type                      Remote Unit   Remote Unit   Remote Unit
Station Rank (1-1000)             1             1             1
Center Frequency                  2.4400 GHz    2.4400 GHz    2.4400 GHz
Security Password 1  (Hex)        1             1             1
Security Password 2  (Hex)        10            10            10
Security Password 3  (Hex)        100           100           100
Security Password 4  (Hex)        1000          1000          1000
Security Password 5  (Hex)        10000         10000         10000
Scrambling Code      (Hex)        0             0             0
Acquisition Code     (0-15)       0             0             0
Config Test Minutes  (1-120)      30            30            30
Tx Power Level Adjust          -> 0 dB          0 dB          0 dB
Base Station Only Parameters
Repeater Mode                     off           off           off
System Symmetry Type              Asymmetric    Asymmetric    Asymmetric
Dynamic Polling Level (1-100)     1             1             1
Remote Station Only Parameters
Remote Unit RF Group (0-63)       0             0             0
Reboot New RF configuration       Press Enter to Execute
Save Current Config to Flash      Press Enter to Execute