Yaesu Musen Co. Ltd. 20311X50 Manuale Utente

Pagina di 137
 
FT-950 
Operating Manual 
Vertex Standard Co., Ltd. 
93 
will appear in the display, and you will hear the results in the sidetone, but no RF 
energy will be transmitted. 
Note: You may adjust the monitor level using the [MONI] knob. 
 
On-The-Air CW Message Playback 
1.  Press the [BK-IN] button to enable transmission. Either Full- or Semi-break-in 
will be engaged, depending on the setting of Menu item “043 A1A BK-IN.” 
2.  Press the FH-2’s [1] ~ [5] key, depending on which CW Memory Register’s message 
you wish to transmit. A “PLAY” icon will appear in the display, and transmit the 
programmed message on the air. 
Note: If you subsequently decide to use the “Message Memory” technique for memory 
storage, please note that the contents of a message stored using text input will not be 
transferred over when you select “Message Memory technique” on a particular memory 
register (the Menu Mode Setting is set to “tyP2”). 
 
Decrementing the Contest Number 
Use this process if the current contest number gets slightly ahead of the actual number 
you want to send (in case of a duplicate QSO, for example). 
Press the FH-2’s [DEC] key momentarily. The current Contest Number will be reduced 
by one. Press the FH-2’s [DEC] key as many times as necessary to reach the desired 
number. If you go too far, use the “Contest Number Programming” technique desired 
previously. 
 
 
FM Mode Operation 
Basic Operation 
1.  Press the [AM/FM] button several times, until the “FM” icon will appear in the 
display, to select the FM operating mode. 
2.  Rotate the Main Tuning Dial knob to select the desired operating frequency. 
Pressing the microphone’s [UP] or [DWN] button will cause frequency change in 5 
kHz steps. 
3.  Press the microphone’s PTT switch (or press the front panel [MOX] button) to 
transmit. Speak into the microphone in a normal voice level. Release the PTT or 
[MOX] switch to return to receive. 
4.  Adjustment of the microphone gain may be accomplished in two ways. At the 
factory, a default level has been programmed that should be satisfactory for most