EMS Technologies Canada Ltd. HSD-400 Manuale Utente

Pagina di 188
Page 4–40
25 June 2008
EMS SATCOM
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-400 High-speed Data Terminal
 9. Press Enter
The load application prompts you to type in a filename.
 10. Type the filename for the software being loaded to the HSD-400 terminal Control 
Processor, and then press Enter
The EMS Loader prompts you to select a COM port.
 11. Type the COM port connected to the HSD-400 terminal, and then press Enter
 12. To start the load, press Enter. (To abort the software load, press Esc.)
Communication with the HSD terminal is established. A percentage (%) load 
status indicator appears on the screen. Once the load is complete, a confirmation 
message briefly appears on the screen indicating that the file has been 
successfully loaded. The DOS window closes and the HSD-400 terminal resets.
 13. If no other software loads are required, proceed to "Verifying Software Loads" on 
Note: If the load fails, restart the load from the beginning of the Loading Control 
Processor Software procedure. If after two attempts the load still does not 
complete successfully, assume that the software disks or files may have been 
corrupted or the software is incompatible with the hardware configuration. 
Contact EMS SATCOM product support for assistance. 
(3) Loading HPA Software
Load HPA software as required according to the applicable software service bulletin 
as released by EMS SATCOM.
 1. Remove power from HSD-400 terminal.
 2. Connect a computer to the Maintenance Port of the HSD-400 terminal. 
 3. Turn on the computer.
 4. Save the EMS Loader application file (ADT_LOAD.exe) to the same folder on 
your computer that contains the software files. (Recommended: Create a folder 
named HSD Load in the root directory and save the load program file and the 
software files to this folder.) 
 5. Apply power to the HSD-400 terminal. 
 6. Close all other applications running on the computer. The load program will not 
execute successfully if other programs are using the com port.
 7. In the HSD folder, double-click ADT_LOAD.exe to launch the load application.
The EMS Loader opens in a DOS window, displays the "Load Target" menu, and 
prompts you to select a ”target” for the software.
 8. To load HPA application software, press 7.
 9. Press Enter.
The system prompts you for a filename.
 10. Type the filename of the HPA software.