EMS Technologies Canada Ltd. HSD-400 Manuale Utente

Pagina di 188
Page 3–4
25 June 2008
EMS SATCOM
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-400 High-speed Data Terminal
Figure 3-1. Fan Tray Plug Configuration (black = installed, white = removed)
C. Chassis Grounding
The HSD-400 terminal tray-mounted assemblies must be electrically bonded to the 
airframe. Ensure the mating surfaces are free from contaminants such as paints or other 
non-conductive elements. Where surface preparations are insufficient to ensure a proper 
bond, the use of a short, tin-coated, copper bonding strap of at least ¼ inch wide is 
recommended. The LRU and tray assemblies should provide a low impedance path of 
<0.2 ohms.
5.
Electrical Installation
This section provides electrical installation details for HSD-400 terminals. This section is 
divided into sub-sections that provide the wiring details for the currently supported modes 
of operation (Stand-Alone Mode only). 
A. Cabling and Connector Requirements
This section provides general electrical installation information on power, ground, 
shielding requirements, and cabling.