E. Connection Details
The tables in this section provide all top, middle, and bottom plug connection details for 
Stand-Alone Mode installations. 
HPA MUTE B
Port BSU-H
HSD-400 TP3B 
STBD BSU-H HSD-400 TP3D
BSU BITE A
BSU-W(G)*
Port BSU-W 
HSD-400 TP2A
STBD BSU-W HSD-400 TP2C
BSU BITE B
BSU-X(H)
Port BSU-X 
HSD-400 TP2B
STBD BSU-X
HSD-400 TP2D
Multi-Control A TP3E
BSU-T(A) & HSD-400 
TP1A
Multi-Control B TP3F
BSU-U(B) & HSD-400 
TP1B
*Letters in (brackets) represent EMS SATCOM AMT-50 BSU pin 
designations
Top/Port (T/P): Refers to Mechanical (fin-mount) High Gain Antenna (HGA) Subsystem
Port:
Refers to Phased Array (Fuselage-mount) or Port side of Dual (side) 
Conformal-mount, HGA subsystem
Starboard 
(STBD): 
Refers to Starboard side of Dual (side) Conformal-mount HGA 
subsystem
 Table 3-9. HSD-400 Terminal to BSU Interconnects (Continued)
Signal Name
Signal Source
Signal Destination
HSD-400 
Terminal
Mechanical 
HGA
Phased-Array 
or Conformal 
HGA
 Table 3-10. Stand-Alone Mode ARINC 600 Top Plug Connection Details 
I/O
From Top 
Plug
Signal Name
To
Description
I
1A
Multi-control A
TP3E
Multi-control from 
control card
I
1B
Multi-control B
TP3F
Multi-control from 
control card
I
2A
BSU Top/Port 
BITE A
(See Note 1)
Mech. Steered Antenna 
(MA): BSU, Pin G or W or 
Other Antenna (OA): BSU, 
PORT-W & Starboard-P 
ARINC Tx-HI BITE 
from Top/Port BSU
I
2B
BSU Top/Port 
BITE B
MA: BSU, Pin H or X, or 
OA: BSU, PORT-X & 
STBD-R
ARINC Tx-LO BITE 
from Top/Port BSU