CALAMP WIRELESS NETWORKS INC. BDD4T881 Manuale Utente

Pagina di 66
120 20170-200
Paragon
PD
 Technical Manual
16
LF
Link Failure - when lit, indicates that the
base station fails to receive an ACK for
a packet sent and for all subsequent re-
tries. Some data has possibly been lost.
LF is not functional if all active ports are
set to NAR mode.
Link fails are inevitable during normal
operation (mobiles temporarily out of
range, in a tunnel, parked in a dead spot,
etc.). A lit LF LED is not normally
cause for concern.
UF
Unit Failure - when lit, the unit requires
attention:
 - the BDLC
PD
 is not operable;
It may indicate detection of a system
software error trap.
- the BDLC
PD
 is operable;
Indicates that on power-up, invalid data
was detected in the serial EEPROM chip
(located in the radio modules). It may
also indicate that connection to the radio
modules is incorrect or that radio power
is not applied.
The LM, RM and UF alarms also sound a beep
when a fault occurs. The LF alarm is silent.
3.2.2 BDLC
PD
 Rear panel
Referring to Figure 4, the rear panel of the
BDLC
PD
 has the following set of chassis con-
nectors:
  Four DE-9F connectors:
–  DEV2 - usually connected to Datara-
dio’s RIS program (DMP/Setup 19200).
Can also be used with special user’s ap-
plication such as telephone modem
Note: connection to a telephone re-
quires the use of a DCE Crossover ca-
ble.
–  DEV3 - Dedicated (9600)
–  DEV4 and DEV5 - not used
  One DB-25F connector
DEV1 - Connects to user’s application.
a)  DMP 19200 for single-site installa-
tions
b)  MSCP 19200 for multi-site installa-
tions
  One DA-15M connector:
DEV6 Digital I/O - not used
  One DB-25M connector:
EXT RADIO/TEST - connects to the
Radio assembly (see Figure 15)
3.2.2.1 Signal 
Levels
In the description of data signals in Table 7, the
following conventions are used:
Table 5 - RS-232 Signal levels
Term
Alternates
Signal level
ON
Asserted, spacing
+3 to +15 V
OFF
Dropped, marking
-3 to -15 V
3.2.2.2 Pin 
Functions
Table 6 - DTE Port 9-pin funtions
DE-9 F
pin #
Function (RS-232 signal levels)
1
DCD – from Paragon
PD
, normally asserted
2
RXD – data from Paragon
PD
3
TXD – data to Paragon
PD
4
DTR – to Paragon
PD
, handshaking
5
Ground
6
DSR – from Paragon
PD
, tied to VCC through
current limiting resistor
7
RTS - to Paragon
PD
, handshaking
8
CTS – from Paragon
PD
, handshaking
9
Reserved
Table 7 - DTE Port 25-pin functions
DB-25F
pin #
Function (RS-232 signal levels)
1 and 7
Ground
2
TXD – data to BDLC
PD
3
RXD – data from BDLC
PD
4
RTS – to BDLC
PD
, must be asserted
5
CTS – from BDLC
PD
, handshaking
6
DSR – from BDLC
PD
, always +8V
8
DCD – from BDLC
PD
, always asserted
9
RI      - from BDLC
PD
, always –8V
20
DTR – to BDLC
PD
, handshaking
We recommend the use of shielded 9-wire or 25-
wire cables with all pins connected.
Dataradio recommends the use of secure (i.e.
password protected and/or dial-back) modems in
any installation where dialup access is provided.