Digital Security Controls Ltd. 06PC5132 Manuale Utente

Pagina di 24
14
Troubleshooting
The RF5132-433 v5.0 features two LEDs to help troubleshoot the operation of the
unit. The LEDs will indicate if the signal received is from an enrolled device or not.
• The green LED will flash when receiving a signal from an enrolled device.
•  The red LED will flash when receiving a signal from a non-enrolled device.
For more precision, when the panel is in placement test mode, the green LED will only
flash for the specific serial number entered. All other signals (including signals from
valid enrolled devices) will flash red.
1.  When I enter the 2-digit zone number when adding a wireless
device, the keypad gives me a long beep.
You cannot  enter ESNs unless a RF5132-433 wireless receiver is connected to the
Keybus. See section 2 for instructions on setting up and wiring the RF5132-433
module.
2.  I have entered the ESN for the device but when I violate the
device, the zone does not show open on the keypad.
Check the following:
• Ensure the ESN has been entered correctly
• Ensure that the zone is enabled for the partition (if partition programming is
used).
• Ensure that the wireless zone is not assigned to a zone used by PC5108
modules, an on-board zone, or a keypad zone.
• Ensure that the zone is programmed for something other than “Null
Operation”, and that the wireless zone attribute is turned on.
3.  When I try a module placement test I get no result or ‘bad’
results.
Check the following (see sections 5.1 and 5.2 for more information on testing
devices):
• Verify that you are testing the correct zone.
• Verify that the correct ESN was entered when the device was enrolled.
• Verify that the device is in range of the RF5132-433. Try testing the device in
the same room as the receiver.
• Confirm that the RF5132-433 is properly connected to the Keybus (see
section 2 for RF5132-433 set up and wiring instructions).
• Check that you are testing the zone correctly (see sections 5.1 and 5.2 for
testing instructions).
• Check that the batteries are working and installed correctly.
• Look for large metal objects that may be preventing the signal from reaching
the RF5132-433.
The device must be located where consistent ‘good’ results are obtained. If several
devices show ‘bad’ results, move the receiver. See section 2.2 for tips on choosing
a mounting location for the RF5132-433.
4.  The LED on the motion detector does not turn on when I walk in
front of the unit.
The LED is for walk test purposes only. See your 
Wireless PIR Instruction Sheet for
walk test instructions.
S E C T I O N  7