Figure 8-4 Alarm Control Unit and 3G Transmitter
 
Alarm
Control
Unit
Zone
Inputs
 TIP 
      
  RING 
 PGM  
Keypad 
LTE Wireless
Communicator
LE4000
T1/R1 
 TIP/RING 
Zone  
Input 
 PGM2 
AUX Power 
12V/500mA 
RM1C ULC 
Relay 
LTE/3G   
PSTN
AC Input 
RM1C ULC 
Relay 
LE4000 cabinet 
NOTES
:
1. Power for LE4000 must be provided from Alarm 
Control Unit or separately listed power supply rated 
for the application (12V/500mA).
2.  Phone Line Monitoring (TLM) must be enabled.
3.  Phone Line trouble is indicated by blue LED on 
LE4000.
4. Connect PGM2 output from LE4000 (Trouble 
Conditions) to a zone input on the Alarm Control 
Unit for supervision of the Transmitter. 
5. 24hr Test Transmission over phone line (PSTN) and 
LE4000 must be enabled. 
6. Connect an output (PGM) from Alarm Control 
panel to an input on the LE4000 to monitor the 
T1/R1 connection.
LE4000 Installation Manual