SERIAL COMMANDS
The INTERACT Serial Commands guide can be found as a separate document. The document
contains a list of applicable serial commands, use and application for the INTERACT AT and
INTERACT PRO models.
Connecting with Telnet
Users can connect to any unit via RS -232 and Telnet. Available Telnet commands are the same as
those used in the Serial Command section of the INTERACT Serial Commands guide.
How to Connect with Telnet:
l
Use the client of your choice
l
Telnet uses port 23
l
The user name and password are the same as used by INTERACT. The default username is
clearone and the default password is INTERACT. These are not case sensitive.
Note: The INTERACT PRO 8i cannot be controlled through RS-232 and Telnet.
RS-232 Port: INTERACT AT/Pro
Pin#
User Definable
Control
1
N
DCD
2
N
TXD
3
N
RXD
4
N
DTR
5
N
Ground
6
N
DSR
7
N
CTS
8
N
RTS
9
N
No Connection
Note: To avoid communication errors, ClearOne recommends using all nine pins
when connecting to the RS -232 port.