6  MESSAGES RECEIVED BY READER 
 
6.1  MODBUS Protocol 
This  is  a  master/slave  protocol.  Each  exchange  is  initiated  by  the  master  and  consists,  except  in  one  case 
(broadcast message), of an exchange of two frames - a command issued by the master and a reply from the 
slave. All frames have the following structure: 
1 byte 
1 byte 
n bytes 
2 bytes 
Slave address 
Function code  
  data   
 control 
 The MOL1312 is a slave on a MODBUS network 
The  commands  issued  by  the  master  are  either  addressed  to  one  slave  (identified  by  its  address)  or  to  all 
slaves on the network  (broadcast). 
Each message or frame contains 4 fields: 
 
The slave address (1 byte): 
Specifies the destination, from 1 to 254. If the address is 0 (zéro), it is a broadcast message. In this case 
there is no reply. 
 
the function code (1 byte): 
Determines  the  type  of  action  to  be  performed  (read,  write,  bit,  word)  and,  in  the  reply,  indicates  if  the 
message was received correctly. 
 
The data field (n bytes): 
Contains the parameters associated with the function: command code, number of bytes, values. 
 
Control field (2 bytes): 
For error detection
 
(CRC 16). 
The  MODBUS  protocol  defines  12  functions  (second  field  in  frame).  Two  of  them  are  implemented  on  the 
MOL81: 
 
function code 3 or 4  
- read n words (*) 
 
function code 16 
 
- write n words 
(*) for reading n words, the MOL 81 accepts function codes 3 and 4. 
 
If  the  message  is  received  with  errors  (CRC  incorrect),  the  reader  does  not  reply.  If  the  message  is  received 
correctly but the reader cannot process it, an error message is sent. This error message has its function code 
field modified, (the msb is set to 1) and the data field contains one byte, an error code with the following values
:
 
 
Error type 
Error code  
Function code unknown 
Command unknown 
Data incorrect 
System non ready 
Execution failure 
 
Figure 6-1: MODBUS error codes