Rosslare Enterprises Ltd AY-L23H Manuale Utente

Pagina di 4
AY-L23 G/H and SA-23 G/H 
Outdoor Long-Range RF Reader and Remote Control 
May 2013
 
Installation and Operation Manual 
1.
  Introduction 
The AYL-23G/H is an outdoor long-range RF reader that acts as a 
receiver. It is compatible with Rosslare’s SA-23 wireless remote control 
transmitter. The AY-L23 G works with the SA-23 G (433.92 MHz) and 
the AY-L23 H works with the SA-23 H (868.35 MHz). 
When the AY-L23 receives the a command signal from the SA-23 
wireless transmitter, the AY-L23 outputs the ID to A_DATA0,A_DATA1 
or B_DATA0,B_DATA1 to the attached controller and controls the 
function of the relay (open drain FET) A or B according to the SA-23 
remote’s command. 
The command signal consists of 3 parts: 
 
ID (in Wiegand format) 
 
ID output to A or B Wiegand Output according to the command in 
SA-23 
 
Relay Function A or B according to command in the SA-23  
Figure 1: AY-L23 G/H and SA-23 G/H 
 
 
AY-L23 G/H 
SA-23 G/H 
2.
  Technical Specifications 
2.1
 
AY-L23 G/H 
Input Voltage 
7 to 24 VDC 
Standby Current 
26 mA (12 VDC) 
Maximum Operating Current 
65 mA (12 VDC) 
Relay (FET, Open Drain) Current  200 mA (max voltage 40 V) 
Tamper Output 
Open collector, active Open, max. sink 
current is 16 mA 
Maximum Cable Distance to 
Controller 
500 ft. (152.4 m) 
Wiegand Output Format
 
Wiegand xbit (Wiegand xbit<=Wiegand 40-
Bit, decided by remote 
Frequencies 
G: 433.92 MHz 
H: 868.35MHz 
Read Range
 
164 ft (50 m) 
Operating Temp. Range
 
-31°C to 63°C (-25°F to 145°F) 
Operating Humidity 
0 to 95% (non condensing) 
Dimensions (L x W x D) 
5.7 x 1.7 x 0.8 in. 
(145 x 43 x 20 mm) 
2.2
 
SA-23 G/H 
Input Voltage 
3 V Battery (CR 2450)  
Standby Current
 
< 1 uA 
Max Operation Current 
10 mA 
ID Format 
Programmed to Wiegand 26-Bit 
Frequencies
 
G: 433.92 MHz (ASK) 
H: 868.35 MHz (ASK) 
Operating Temp. Range 
-31°C to 63°C (-25°F to 145°F)  
Operating Humidity 
0 to 95% (non condensing)  
Dimensions (L x W x D) 
2.28 x 1.61 x 0.53 in. 
(58 x 41 x 13.4 mm) 
3.
  Mounting Instructions 
Determine an appropriate mounting position for the receiver. Do not 
mount the receiver near any source of wireless interference or on any 
metal surface. 
To mount the receiver: 
1.
  Peel off the back of the self-stick mounting label template included 
with the unit and place at the desired mounting position. 
2.
  Using the template as a guide, drill two holes (hole size is indicated 
on mounting template) for mounting the receiver to the surface. 
3.
  Drill a 7/16” (10-mm) hole for the cable. 
4.
  Remove the front case from the receiver. 
5.
  Attach the receiver to the controller. (See wiring instructions) 
6.
  Screw the receiver’s rear case onto its mounting location and 
return the front case onto the mounted rear case. 
The receiver is to be used with control panels whose power supply is 
UL Listed Class 2 or equivalent.