Visonic Inc. DUETAM Manuale Utente

Pagina di 4
D-300431 
3. INSTALLATION
3. INSTALLATION
3. INSTALLATION
3. INSTALLATION    
3.1 Installation Tips 
To minimize false alarms: 
Do not aim at heat sources 
 
Mount on solid, stable surfaces 
 
Do not expose to air drafts 
 
Do not install outdoors 
 
Prevent direct sunlight from 
reaching the detector 
 
Keep wiring away from 
electrical power cables 
 
Do not install behind partitions 
 
 
In addition, a few important rules must be observed while selecting a 
mounting location:  
A.  Microwave radiation passes through glass and non-metallic walls. 
Be sure to adjust the MW range so that it does not exceed the 
room limits, or else motion in the next room or moving traffic 
along the outer side of the wall will cause the MW sensor to trip. 
B.  Large reflecting objects (especially metals) in the coverage area 
can distort the microwave sensor's coverage pattern. 
C.  If two DUET-AM C/O units are installed in the same room or on 
opposite sides of a shared wall, they should not face each other 
and must be mounted at least 2 meters apart. 
D.  Do not install the DUET-AM C/O in places where one of the two 
sensor circuits alarms constantly or intermittently, due to 
environmental interference. 
E. DUET-AM C/O users are advised to mount the unit in 
locations where inadvertent approach to less than 1 m (3 ft) 
from the detector is unlikely to occur. 
3.2 Mounting 
A.  Remove the front cover as shown in Figure 3.
 
IMPORTANT: When re-mounting the cover, remember to fasten 
the screw well - this will force the tamper switch actuator upon the 
tamper switch and will press it fully in. 
B.  Loosen the vertical adjustment screw, slide the PCB up and 
remove it via the “keyhole” (see Figure 4). 
C.  Put the PCB aside until required again. 
D.  Refer to Figure 5 and punch out the mounting knockouts at 
the rear of the base (for surface mounting) or at the angled 
sides (for corner mounting). 
E.  Punch out any one of the wiring knockouts shown in Figure 5. 
 
 
Figure 3. Cover Removal 
 
F.   Hold the base against the wall at the selected installation location, 
mark the points for drilling and drill the holes. Insert the plastic 
dowels (supplied) if necessary.  
G.  Pass the wires through the wiring inlets into the base and attach 
the base to the wall using the screws (supplied). 
H.  Return the PCB to its place within the base. 
I.  Proceed to wire the terminal block as instructed in Para. 3.3. 
ALARM TROUBLE EOL TAMP
TST
12V
FAR
MID
NEAR
DUET AM
MIN
MAX
ON
1
2
3
4
TERMINAL
BLOCK
PIR
SENSOR
MODE
SELECTOR
TAMPER SWITCH (HIDDEN
UNDER ACTUATOR)
DUAL
COLOR
LED
KEYHOLE
SHAPED
SLOT
MW
MODULE
VERTICAL
ADJUST.
SCALE
MW LEVEL
CONTROL
 
Figure 4. PCB Layout 
 
SURFACE
MOUNTING
KNOCKOUTS
CORNER
MOUNTING
KNOCKOUTS
WIRING
KNOCKOUTS
CORNER
MOUNTING
KNOCKOUTS
POINT
TAMPER SWITCH
ACTUATOR
 
Figure 5. Base after PCB Removal 
3.3 Wiring 
Refer to the following illustrations and wire up the terminal block, 
according to DIP switch 3 position.