Climax Technology Co Ltd CTC1052RV Manuale Utente
17
z
To set the microphone sensitivity with a
number, ranging 1 to 5. This value
represents the received sound source
range. The higher the value, the wider
range of sound source. Factory default is
set as (3).
represents the received sound source
range. The higher the value, the wider
range of sound source. Factory default is
set as (3).
z
Please refer to programming command
table section for configuration.
table section for configuration.
<
<
N
N
O
O
T
T
E
E
>
>
)
The sensitivity level in the Listen In or
Talk-Only mode is adjusted for the
best communication quality. It is fixed
and can not be changed.
best communication quality. It is fixed
and can not be changed.
)
Echo volume varies depending on
adjustment of speaker volume and
microphone sensitivity. To minimize
the impact of echo, if you raise
speaker volume, please be sure to
lower microphone sensitivity, and vice
versa.
microphone sensitivity. To minimize
the impact of echo, if you raise
speaker volume, please be sure to
lower microphone sensitivity, and vice
versa.
)
The call recipient can not adjust
speaker volume values if the
communication is set up between
WTRV/ WTRVS and himeself.
communication is set up between
WTRV/ WTRVS and himeself.
Command 66
Guard Time Delay for Fall Sensor
z
This command is used to set the guard
time delay time for fall sensor.
z
CTC-1052RV can be programmed to delay
alarm reporting (triggered by Fall Sensor)
from (00) (instant reporting) to (99)
seconds.
from (00) (instant reporting) to (99)
seconds.
z
During this time period, a continuous series
of beeps will be emitted to alert user.
z
If a false alarm is triggered by Fall Sensor,
it can be cancelled within the Guard Time
Delay.
Delay.
Function
Selection
Result
(00) INSTANT
REPORTING
(01) - (99)
DELAY
z
Factory Default is (15), 15 SECONDS.
<
<
N
N
O
O
T
T
E
E
>
>
)
If an emergency alarm is triggered by
pressing the Active Button on Fall
sensor, the guard time delay time is
restricted to Command 42, rather
than Command 66.
sensor, the guard time delay time is
restricted to Command 42, rather
than Command 66.
)
The Guard Time Delay for Fall Sensor
is set by Command 66. This
command is used if a fall is detected.
command is used if a fall is detected.
Command 80-84
Remove Devices
z
CTC-1052RV can be programmed to
remove ALL previously learnt devices by
entering (80) followed by (#). The system
will emit an acknowledging beep over the
phone for the user.
remove ALL previously learnt devices by
entering (80) followed by (#). The system
will emit an acknowledging beep over the
phone for the user.
z
Command (81) is used to remove Pendant
# 1 (learnt-in by Command 91)
# 1 (learnt-in by Command 91)
z
Command (82) is used to remove Pendant
# 2 (learnt-in by Command 92).
# 2 (learnt-in by Command 92).
z
Command (83) is used to remove Silent
Wrist (learnt-in by Command 93).
Wrist (learnt-in by Command 93).
z
Command (84) is used to remove Other
Devices (learnt-in by Command 94).
Devices (learnt-in by Command 94).
<
<
N
N
O
O
T
T
E
E
>
>
)
Power Switches are not to be removed
by any Command. They are to be
removed by clearning their own
memory. Please refer to the Power
Switch’s manual to proceed.
removed by clearning their own
memory. Please refer to the Power
Switch’s manual to proceed.
Command 91
Learn-In Pendant #1
<
<
N
N
O
O
T
T
E
E
>
>
)
This command is not available in
Remote Programming Mode.
z
Only one Pendant (WTR- Series or Fall
Sensor) can be learnt into CTC-1052RV by
using Command #91.
Sensor) can be learnt into CTC-1052RV by
using Command #91.
z
If you have learned one device into the
system by using local learning method (as
mentioned in 2.1 section), you are not
allowed to use Command 91 to learn in
another device.
system by using local learning method (as
mentioned in 2.1 section), you are not
allowed to use Command 91 to learn in
another device.
z
For learning Pendant #1:
Step 1: Enter 91 + # on the phone set, then