he Smoke Detector will transmit a supervision signal to report its condition regularly according to 
user setting. The factory default interval is 30 minutes. The user can also press the Function Button 
once to transmit a supervision signal manually. 
 
ZigBee Network Setup 
z
z
 
 
Z
Z
i
i
g
g
B
B
e
e
e
e
 
 
D
D
e
e
v
v
i
i
c
c
e
e
 
 
G
G
u
u
i
i
d
d
e
e
l
l
i
i
n
n
e
e
 
 
ZigBee is a wireless communication protocol that is reliable and has low power consumption and 
high transmission efficiency. Based on the IEEE802.15.4 standard, ZigBee allows a large amount 
of devices to be included in a network and coordinated for data exchange and signal transmission. 
Due to the fundamental structure of ZigBee network, ZigBee device will actively seek and join 
network after powering on. Since performing a task in connecting network may consume some 
power, it is required to follow the instructions to avoid draining battery of a ZigBee device 
- Ensure your ZigBee network router or coordinator is powered on before inserting battery into the 
ZigBee device. 
- Ensure the ZigBee network router or coordinator is powered on and within range while a ZigBee 
device is in use. 
- Do not remove a ZigBee device from the ZigBee network router or coordinator without removing 
the battery from a ZigBee device. 
z
z
 
 
J
J
o
o
i
i
n
n
i
i
n
n
g
g
 
 
t
t
h
h
e
e
 
 
Z
Z
i
i
g
g
B
B
e
e
e
e
 
 
N
N
e
e
t
t
w
w
o
o
r
r
k
k
 
 
As a ZigBee device, the Smoke Detector needs to join a ZigBee network to transmit signal when 
smoke concentration is detected. Please follow the steps bellow to join the Smoke Detector into 
ZigBee network. 
1. Insert the batteries into the battery compartment to power on the Smoke Detector. 
2. The Smoke Detector will begin warm up for 6 minute, the LED will flash every second. 
3. Joining ZigBee network is allowed during the 6-minute warm up period. Press and hold the 
function button for 10 seconds and release to search for existing ZigBee network. Please make 
sure the permit-to-join feature on the router or coordinator of your ZigBee network is enabled. 
4. After joining the ZigBee network, the Smoke Detector will be registered in the network 
automatically. Please check the ZigBee coordinator, security system control panel or CIE 
(Control and Indicating Equipment) to confirm if joining and registration is successful. 
5. After the 6-minute warm up period expires, the Smoke Detector will enters calibration process. 
The calibration process takes about 2-16 minutes; the LED will continue to flash during 
calibration. Joining ZigBee network is prohibited during calibration process. 
6. When calibration is complete, the Smoke Detector will emit 2 beeps and LED will stop flashing to 
indicate it is now under normal operation. 
7. Under  normal  operation,  if the Smoke Detector loses connection to its current ZigBee network, 
the LED indicator will flash every 20 minutes to indicate the situation. Please check your ZigBee 
network condition and Smoke Detector signal range to correct the situation. 
z
z
 
 
F
F
a
a
c
c
t
t
o
o
r
r
y
y
 
 
R
R
e
e
s
s
e
e
t
t
 
 
If you want to remove the Smoke Detector from current network and join a new network, you need 
to use the Factory Reset function to clear the Smoke Detector of its stored setting and information 
first before it can join another network. To perform Factory Reset: 
1. Press and hold the function button for 10 seconds, release the button upon hearing two short 
beeps. 
2. The Smoke Detector has been reset to factory default setting with all its previous network 
information removed. It will now actively search for available ZigBee network again and join the 
network automatically.   
3. If the Smoke Detector successfully joins a ZigBee network, the LED Indicator will flash twice to 
indicate.