To  control  the  fan  and  lights  from  two 
locations  (a  three-way  circuit),  use  two  
W-74 wall controls.
1. Remove the screws and switch plate from 
the existing switch box and the screws 
holding the switch in the switch box.
2. Pull the existing switch from the switch 
box to expose the wire connections.
3. Determine which wire is connected to the 
common terminal from the power source 
(120V AC) of the three-way switch. (The 
terminal will be marked on switch).
4. Remove  the  wire  from  the  common 
terminal  of  the  three-way  switch. 
Connect  this  wire  to  the  remaining 
black/white striped wire on the W-74 
control. Secure this splice with a wire 
nut.
5. Remove  the  two  remaining  wires 
from  the  three-way  switch.  Connect 
the  black  wire  of  these  wires  to 
a  black  wire  on  the  W-74  control. 
Secure  the  splice  with  a  wire  nut. 
The  remaining  red  wire  is  to  be 
connected to the other red wire on the  
W-74.  Secure  the  splice  with  a  wire 
nut.
6. Connect the green ground wire coming 
from the back of the W-74 control to the ground wire in the switch box. Secure the 
splice with a wire nut.
7. Check your work by using the wiring diagrams as shown in Figure #5 on this page. 
8. Install the W-74 in the wall box with the two long screws provided.
9.Install the wall plate with the two short color-matched screws provided.
10.Installation of the second W-74 control is identical. Repeat steps 1 through 9.
 
W-74 WALL CONTROL    
 
INSTALLATION
(For use on product with BOTH UP and DOWN LIGHTS ONLY)
Setting the Frequency
DIP SWITCHES
(FIGURE #2)
To use this switch with an existing W-74 wall switch, 
you must first set the jumpers on the new switch to 
match that of the existing one.
 
1. Turn off power to the existing wall switch.
 
2. Using a screw driver, remove the (2) wall plate 
screws,  then  remove  the  (2)  switch  mounting 
screws.
3. Gently remove the existing wall switch from the 
wall and locate the dip switches located on the 
side of the switch.
4. Change the dip switches on the new wall switch 
to match the exisiting. (FIGURE 2)
5. Reinstall the existing wall switch.
inStalling the Wall control
The wall control installs in the same manner as an ordinary light switch, using an existing 
wall box and wiring. This controller is designed to signal the fan microcomputer as well 
as perform normal switching operations. For this reason the following precautions must 
be observed:
1. Use only the Casablanca W-74 wall control.
2. Do not use any additional control with your Direct-Touch™ fan (for example, dimmer, 
or fan speed control).
3.  Do not use more than one fan per wall control.
4.  No other light fixtures or electrical appliances may be connected on the circuit con-
trolled by the W-74 wall control.
single W-74 installation
CAUTION! 
Ensure power is turned OFF at the breaker or fuse panel before starting 
installation.
If you have multiple Direct-Touch
 fans, 
refer to the section "Channel Changing".
1. Remove  the  screws  and  switch  plate 
from the existing switch box.
2. Remove the screws holding the switch 
in the switch box.
3. Pull the existing switch from the switch 
box to expose the wire connections.
4. Remove the two wires from the switch.
5. Connect  the  BLACK  wire  from  the 
POWER SOURCE that you just removed 
from the switch to the BLACK/WHITE 
STRIP wire on the W-74 wall control. Secure this connection with a wire nut.
6. Connect the second BLACK wire that 
you  just  removed  from  the  switch  to 
the second BLACK wire on the located 
on the back of the W-74 wall control. 
Secure this connection with a wire nut.
7. Connect the green ground wire coming 
from the back of the W-74 control to the 
ground wire in the switch box. Secure 
the splice with a wire nut.
NOTE:  The  RED  wire  is  not  used  in 
this application. DO NOT remove the 
crimped cap from the wire.
8. Check your work by using the wiring 
diagrams as shown in Figure #3.
9. Install the W-74 in the wall box with the two long screws provided.
10. Install the wall plate with the two color-matched screws.
Dual W-74 installation
To control the fan and lights from two locations (a three-
way circuit), use two W-74 wall controls as shown in 
the wiring diagram in Figure #5. Before installing 
the two switches into the wall, place both switches 
side by side, then locate the 4 dip switches on the 
side of the two switches. Then make sure that the 
dip switches are set to the same address on both 
switches as shown in Figure #4. When setting these 
dip switches you are setting the channel number 
that is required to control both your fan and lights 
from both sides of the room. If you are installing 
other Direct-Touch™ fans within your home you 
may need to reset the dip switches on these other 
fans to a different channel before installing your 
W-74 wall control into the wall. Please review the 
section  on  channel  changing  on  this  instruction 
sheet.
channel changing
Each fan must operate on it’s own frequency to prevent interference. Fan frequencies 
are set by the dip switch settings on the W-74 wall control (other than to match an 
existing W-74 controlling the same fan). To synchronize the fan to the new frequncy:
1. Turn the power OFF to the fan and W-74 you want to synchronize.
2. Turn the power back on to the fan and W-74 wall control.
3. Within 20 seconds of restoring power to the ceiling fan and the W-74 Wall Control 
press and hold both the “1” and 
1
2
0
4
3
 reverse buttons. For 3 seconds, you will hear 
one tone from the Piezo Buzzer indicating the command has been accepted. The 
Fan and Lights will be off. 
CAUTION! 
Ensure power is turned OFF at the breaker or fuse panel before starting 
installation.
W-74 Wall control HardWare
Wall Plate 
Screws (2)
Switch 
Mounting
Screws (2)
(4) Wire Cap
W-74
Wall Control
Cover Plate
Warning!
To avoid possible electrical shock, make 
certain that electricity is turned off at 
the circuit breaker or fuse box before 
attempting any installation or repair 
procedure
CAUTION! NOT turning the power 
OFF at the circuit breaker or fuse box 
may cause damage to the electronics 
within the wall control and or the PC 
board on the fan. 
W-74 Wall control PreParation
Circuit Breaker
(trip breaker for the
circuit you will be
working on)
Fuse Box
(Remove fuse for the
circuit you will be
working on)
BLACK AND WHITE
STRIPED WIRE
2 BLACK
WIRES
RED WIRE
NOT USED
(FiGUre #3)
(FIGURE #4)
DIP SWITCHES
BLACK
BLACK
RED
GREEN
120V AC
BLACK
BLACK WITH
WHITE STRIPE
W-74
RED
RED
RED
BLACK WITH
WHITE STRIPE
GREEN
W-74
BLACK
BLACK
BLACK
BLACK
BLACK
NEUTRAL
WHITE
GREEN
(FIGURE #5)
W-74
Wall Control
BLaCK anD WHiTE
STriPED WirE
2 RED WIRES
2 BLaCK
WirES
(FIGURE #6)
W-74
Red
White
Blue
Black/White