Codan Radio Communications AMP-3-150 Manuale Utente

Pagina di 12
VHF 30W Power Amplifi er Instruction Manual
IM71-AMP3150-30
General Information
3
PHYSICAL SPECIFICATIONS
Operating Temperature Range:  
-30
º
C to +60
º
C, optional -40
º
C temperature test.
Operating Humidity: 
Up to 95% RH (non-condensing) at +25
º
C
RF Connectors: 
Type N Standard
Corrosion Prevention: 
Anodized aluminum construction.  Stainless steel hardware.
Physical 
Dimensions: 
Width: 
 
 Height: 
 Depth:
14.2 cm (5.6”) 
12.8 cm (5.05”)  19 cm (7.5”)
Weight: 
2.4 kg. (5.5 lb.)
Features: 
•Heavy Duty Aluminum Heatsink;
•Thermal switched Fan (at 40
º
C).
•RF Power, High VSWR, Overload and Overtemp Indicators.
•Internal, re-settable circuit breaker