selected a status signal is sent to the PCI reporting the mode selection. Loss of flow for 
more than 5 seconds in an active pump will cause activation of the standby pump. Loss 
of flow for more than 15 seconds will cause both pumps to shut down.
1.2.8.3
PA Module and Combiner Cold Plates
Each PA Module has a liquid cooled cold plate which connects to the cooling system 
with quick release connectors. There are also cold plates inside the combiner and the 
splitter to which all of the internal combiner reject loads are attached. See Figure 1-12 
for cabinet coolant routing and module slot numbering.
NOTE:
The module slot numbering should not be confused with the IPA and PA module 
numbering.  Module numbering and slot locations will vary depending on model 
number. See the outline drawing to identify which PA modules go in which slot 
locations dependent on model.