NEC Corporation FC-N22A Manuale Utente

Pagina di 173
 
153
 
M
a
in
te
n
a
n
ce
 
·  Silicon disk size 
: Cp = 8,000,000 [KB] 
·  Write target area size 
: Da [Byte] = 8,000,000 [KB] 
·  Write target block 
: DaB [block] = 16,000 [blocks] 
·  Rewrite data size 
: X [KB] 
·  Rewrite frequency per hour  : Z [no. of times/hour] 
·  Operating time per day 
: H [hours] 
·  Operating days per year 
: D [days] 
·  Number of blocks used for 1 rewrite of data size X: 
A=ROUNDUP(X / 512 [KB]) 
 4 = [No. where decimal point of X / 512 [KB] is rounded up]  4 
 
* Rewrite life [Years] (reference value) = (100,000 times 
 DaB) / (Z  A  H  D). 
 
 
6.3.2  Service Menu   
 
The following FC98-NX Series Support Pack maintenance pack is offered. Three service types 
can be selected. 
 
1)  On-site repair service 
A service engineer visits the installation site and repairs the system when a problem occurs.   
 
2)  Pick-up repair service   
A company assigned by NEC picks up the device and delivers the repaired one. 
 
3)  Delivery repair service   
The customer sends the device with a failure to our repair center for repair.