Tyco Safety Products/Sensormatic APS1000 Manuale Utente

Pagina di 2
APS-1000 Quick Install Guide 
 
1.8 Meter (6-Foot) Doorway System 
 
(Preliminary) 8000-2853-06, Rev. 0 
 
APS-1000 Marketed as 
AssetPro
SM
 and ezMax
 
C
L
C
L
B
C
B
D
D
Tx
A
 
a
b
 
Tx
B
C
!
A
  
The APS-1000 uses a primary pedestal 
and a secondary pedestal (the one with 
the long cable attached). 
A.  The base for the primary pedestal 
contains a cable connection bracket. 
Remove this bracket from the base. 
Four screws secure the bracket. 
B.  Place pedestal bases 1.5–1.8m  
(5–6 feet) apart, center-to-center.  
VERY IMPORTANT! 
Ensure bases  
are at least 12.7cm (5 in.) from the  
doorframe.  
C. 
Using a pencil, mark mounting hole 
locations for each base. If drilling 
through carpet, cut the carpet to 
avoid carpet runs. 
 
D. 
Move the bases out of the way and, 
using a 1.25cm (1/2 in.) drill bit, drill 
mounting holes 9cm (3 in.) deep.
 
Secure each base using screws (a) and 
anchors (b) supplied. 
With its bottom facing the doorway, 
gently lay the secondary pedestal near 
its base. In the base, run the cable 
through the Romex clamp in the lower 
hole facing the door. Tighten the Romex 
clamp. 
Ensuring the pedestal’s cover screws 
face the exit, press down for a tight fit. 
As you do, pull excess cable out of the 
base. Ensure the cable is not pinched 
between the base and the pedestal 
housing. 
IMPORTANT!
 Once the pedestal is in 
place, gently push about 0.3m (1ft) of 
cable back into the base to enable the 
pedestal to be detached from the base if 
future service is required.  
 
 
Peel and stick wireway is provided. The 
cable from the secondary pedestal to the 
primary pedestal runs up, over and down 
the doorway through this wireway. 
A.  Wipe the frame of the door with 
alcohol where the wireway is to go. 
Then with the opening of the wireway 
facing the exit, affix the wireway 
around the doorframe (shown by 
arrows) and insert the cable into it. 
B.  At the base of the primary pedestal, 
run the end of the cable through the 
Romex Clamp in the lower hole in  
the end facing the door so it’s end 
extends about 30.5cm (1 ft) above 
the base. Cut off and discard excess 
cable. 
C.  If necessary, protect any remaining 
exposed cable with a wireway or 
other suitable covering. 
 
A.  At the cable connection bracket, 
connect the cable (and any 
accessory cables) to the color-
coded terminal blocks at the bottom 
of the bracket. 
5-pin terminal block
Pin 1 — Secondary top 
Pin 2 — Return secondary top 
Pin 3 — Return secondary bottom 
Pin 4 — Secondary bottom 
Pin 5 — Shield 
14-pin terminal block: 
Pin 1 — Remote transmit enable 
Pin 2 — Return Remote transmit enable 
Pin 3 — Shield 1 
Pin 4 — Secondary antenna select 
Pin 5 — Return secondary antenna select 
Pin 6 — Shield 2 
Pin 7 — Relay 1 
Pin 8 — Common 1 
Pin 9 — Relay 2 
Pin 10 — Common 2 
Pin 11 — Shield 3 
Pin 12 — W Sync 
Pin 13 — Return W Sync 
Pin 14 — Shield 4
 
B.  Re-insert the cable connection 
bracket back into the base and 
secure using the four screws 
previously removed.  
C.  Ensure the connector on the 
bracket faces away from the door. 
1
2
3
4
5