Tyco Safety Products/Sensormatic DEACLCD Manuale Utente
ZBAMB2010T TABLETOP DEACTIVATOR INSTALLATION GUIDE (8200-0185-01, REV. A)
1 of 3
ZBAMB2010T
Tabletop Deactivator
Tabletop Deactivator
Installation Guide
The AMB-2010 tabletop deactivator consists of the
deactivator unit and a class 2 external power
supply that plugs into an ac outlet. The power LED
glows green when power is applied.
deactivator unit and a class 2 external power
supply that plugs into an ac outlet. The power LED
glows green when power is applied.
The deactivator deactivates UltraStrip II and III
security labels rubbed and swirled on its surface.
The deactivate field is 10cm (4 in.) square and
7.5cm (3 in.) high. Deactivation is indicated by the
power LED pulsing orange and a long beep.
security labels rubbed and swirled on its surface.
The deactivate field is 10cm (4 in.) square and
7.5cm (3 in.) high. Deactivation is indicated by the
power LED pulsing orange and a long beep.
WARNING:
Do not deactivate labels on
audio or videotapes. The deactivate field
is not magnetic media safe.
is not magnetic media safe.
The deactivator is intended to be installed “as is”
without adjustments. If adjustments are necessary,
a laptop computer containing special configuration
software can be connected to a jack at the rear of
the deactivator.
without adjustments. If adjustments are necessary,
a laptop computer containing special configuration
software can be connected to a jack at the rear of
the deactivator.
Please observe the following safeguards before
you begin installation.
you begin installation.
WARNING:
Hazardous areas.
DO NOT install the deactivator where
highly combustible or explosive products
are stored or used.
highly combustible or explosive products
are stored or used.
WARNING:
RISK OF ELECTRIC
SHOCK!
Deactivator has no user-serviceable
parts! DO NOT attempt to open the
deactivator.
Power Cord. The cord cannot interfere
with the operation of cash drawers,
conveyor belts, or with the operation,
maintenance or removal of equipment.
parts! DO NOT attempt to open the
deactivator.
Power Cord. The cord cannot interfere
with the operation of cash drawers,
conveyor belts, or with the operation,
maintenance or removal of equipment.
© Sensormatic 2002
If you need assistance…
Call 1-800-241-6678
(Sensormatic / ADT Customer Response Center).
(Sensormatic / ADT Customer Response Center).
Cleaning the Deactivator
Clean exterior surface using a soft cloth moistened
with warm, soapy water. Dry thoroughly. DO NOT
use solvents or scouring cleanser.
with warm, soapy water. Dry thoroughly. DO NOT
use solvents or scouring cleanser.
Deactivation Status Indications
Status LED Tone
Power On
Sequence
Sequence
Flashing Green
(for 10 seconds)
(for 10 seconds)
Short Beep
Ready Green
Deactivate
Deactivate
Pulsing Orange
Long Beep
Transmit Off
Flashing Green
Fault Condition
Red
Hard Tag
Present
Present
Continuous
Short Beep
Install Kit Required
Install Kit 0352-0101-01
Deactivator Assy.
1
0303-0038-01
Template, Cutout
1
8000-2699-02
Velcro, Hook, w/Adhesive
.5ft
3200-0358-01
Velcro, Loop, w/Adhesive
.5ft
3200-0358-02
Cable Tie, 5-1/2"L x 16"W, Nylon
3
6009-0001
Mount, Adhesive Backed, 1-1/8 sq.
3
6009-0003
Clamp, Cable, Nylon, .313D, .172MTG 2
6010-0035-10
Screw, Self-Tapping, 3.5x16 PHP
2
5810-3051-120
Label, Keep Magnetic Media Away
1
2402-1301-01
Pad, Alcohol
2
1600-0033
Tools Required
§ Power drill and drill bits
§ Phillips screwdriver
§ Hand vacuum and broom.
§ Phillips screwdriver
§ Hand vacuum and broom.
Proper Placement
§ DO NOT install the deactivator over a metal
surface. Deactivator fields interact with metal
causing deactivator performance to degrade.
causing deactivator performance to degrade.
§ The field from the deactivator can interact with
certain POS equipment. Avoid placing the
deactivator too close to POS equipment.
deactivator too close to POS equipment.
!
!